Evidence map›Paper›PMID 35578057›Full record

ArticleEuropean radiology experimental2022

Tantalum-specific contrast-to-noise ratio or conventional detector dose-driven exposure control in angiography: radiation dose and image quality evaluation in a porcine model.

Thomas Werncke, Timo Christian Meine, Jan B Hinrichs, Sabine K Maschke, Lena Sophie Becker, Inga Brüsch, Regina Rumpel, Frank K Wacker, Bernhard C Meyer

Open access · goldAbstract read
In one paragraph

Article in European radiology experimental, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Thomas WernckeDepartment of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany. Werncke.Thomas@mh-hannover.de.ORCID http://orcid.org/0000-0002-4043-5506
Timo Christian MeineDepartment of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.
Jan B HinrichsDepartment of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.
Sabine K MaschkeDepartment of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.
Lena Sophie BeckerDepartment of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.
Inga BrüschInstitute for Laboratory Animal Science and Central Animal Facility, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.
Regina RumpelInstitute for Laboratory Animal Science and Central Animal Facility, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.
Frank K WackerDepartment of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.
Bernhard C MeyerDepartment of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.
Medizinische Hochschule Hannover · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe aim of this animal study was to compare the fluoroscopic image quality (IQ) and radiation dose between a tantalum (Ta)-specific contrast-to-noise ratio-driven exposure control (Ta-CEC) and a detector dose-driven exposure control (DEC) in abdominal angiography.

methodsNine angiography scenarios were created in seven anaesthetised pigs using Ta-based embolisation material during percutaneous liver and kidney intervention. Fluoroscopic images were acquired using three DEC protocols with different dose levels and Ta-CEC protocols with different IQ levels, sampled in small steps. Polymethyl-methacrylate and aluminium plates were used to simulate attenuation of three water equivalent thicknesses (WET). Three blinded readers evaluated the IQ of DEC and dose equivalent Ta images and selected the Ta-IQ equivalent image corresponding to the DEC image.

resultsInterobserver agreement for the IQ assessment was 0.43 for DEC, 0.56 for Ta-CEC and for the assessment of incident air kerma at the interventional reference point (K

conclusionsCompared to DEC, Ta-CEC significantly improved the fluoroscopic depiction of Ta, while maintaining the K

Indexed as

AngiographyTantalumAnimalsFluoroscopyPhantoms, ImagingRadiation DosageSwineTantalumAngiography (digital subtraction)AnimalsFluoroscopyRadiation dosageTantalum

Identifiers

PMID35578057
PMCPMC9110612
OpenAlexW4280535031

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.