Evidence map›Paper›PMID 35577344›Full record

ArticleNMR in biomedicine2022

Proton metabolic mapping of the brain at 7 T using a two-dimensional free induction decay-echo-planar spectroscopic imaging readout with lipid suppression.

Kyung Min Nam, Arjan D Hendriks, Vincent O Boer, Dennis W J Klomp, Jannie P Wijnen, Alex A Bhogal

Abstract read
In one paragraph

Article in NMR in biomedicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kyung Min NamCenter for Image Sciences, Department of Radiology, University Medical Centre Utrecht, Utrecht.ORCID 0000-0002-9185-3986
Arjan D HendriksCenter for Image Sciences, Department of Radiology, University Medical Centre Utrecht, Utrecht.ORCID 0000-0002-0363-2471
Vincent O BoerDanish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark.
Dennis W J KlompCenter for Image Sciences, Department of Radiology, University Medical Centre Utrecht, Utrecht.
Jannie P WijnenCenter for Image Sciences, Department of Radiology, University Medical Centre Utrecht, Utrecht.
Alex A BhogalCenter for Image Sciences, Department of Radiology, University Medical Centre Utrecht, Utrecht.ORCID 0000-0003-3211-1760

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The increased signal-to-noise ratio (SNR) and chemical shift dispersion at high magnetic fields (≥7 T) have enabled neuro-metabolic imaging at high spatial resolutions. To avoid very long acquisition times with conventional magnetic resonance spectroscopic imaging (MRSI) phase-encoding schemes, solutions such as pulse-acquire or free induction decay (FID) sequences with short repetition time and inner volume selection methods with acceleration (echo-planar spectroscopic imaging [EPSI]), have been proposed. With the inner volume selection methods, limited spatial coverage of the brain and long echo times may still impede clinical implementation. FID-MRSI sequences benefit from a short echo time and have a high SNR per time unit; however, contamination from strong extra-cranial lipid signals remains a problem that can hinder correct metabolite quantification. L2-regularization can be applied to remove lipid signals in cases with high spatial resolution and accurate prior knowledge. In this work, we developed an accelerated two-dimensional (2D) FID-MRSI sequence using an echo-planar readout and investigated the performance of lipid suppression by L2-regularization, an external crusher coil, and the combination of these two methods to compare the resulting spectral quality in three subjects. The reduction factor of lipid suppression using the crusher coil alone varies from 2 to 7 in the lipid region of the brain boundary. For the combination of the two methods, the average lipid area inside the brain was reduced by 2% to 38% compared with that of unsuppressed lipids, depending on the subject's region of interest. 2D FID-EPSI with external lipid crushing and L2-regularization provides high in-plane coverage and is suitable for investigating brain metabolite distributions at high fields.

Indexed as

Echo-Planar ImagingProtonsBrainHumansLipidsMagnetic Resonance ImagingMagnetic Resonance SpectroscopyLipidsProtons7 Tcrusher coilEPSIFIDL2-regularizationlipid suppressionMRSIpulse acquire

Identifiers

PMID35577344
PMCPMC9541868

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.