Evidence map›Paper›PMID 35576128›Full record

ArticleMagnetic resonance in medicine2022

Accuracy investigations for volumetric head-motion navigators with and without EPI at 7 T.

Mads Andersen, Malte Laustsen, Vincent Boer

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Mads AndersenPhilips Healthcare, Copenhagen, Denmark.ORCID 0000-0002-2702-1640
Malte LaustsenCenter for Magnetic Resonance, Department of Health Technology, Technical University of Denmark, Lyngby, Denmark.
Vincent BoerDanish Research Center for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital - Amager and Hvidovre, Copenhagen, Denmark.ORCID 0000-0001-6026-3134

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeAccuracy investigation of volumetric navigators for motion correction, with emphasis on geometric EPI distortions at ultrahigh field.

methodsHigh-resolution Dixon images were collected in different head positions and reconstructed to water, fat, T

resultsIncreased accuracy was observed with increased spatial resolution for non-EPI navigators. When using EPI, the distortions had a negative effect on registration accuracy, which was most noticeable for high-resolution navigators. Parallel imaging helped to alleviate those caveats to a certain extent, and 5-fold acceleration gave close to similar accuracy to non-EPI in most cases. Shortening the TE by partial Fourier sampling was shown to be mostly beneficial, except for water navigators with long readout durations. The EPI blip direction had an influence on navigator accuracy, and positive blip gradient polarities (yielding mostly image stretching frontally) typically gave the best accuracy for water navigators, whereas no clear recommendation could be made for fat navigators. Generally, fat EPI navigators had lower accuracy than water EPI navigators with otherwise similar parameters.

conclusionsEcho planar imaging has been widely used for MRI navigators, but the induced distortions reduce navigator accuracy at ultrahigh field. This study can help protocol optimization and guide the complex tradeoff between resolution and EPI acceleration in navigator parameter setup.

Indexed as

ArtifactsEcho-Planar ImagingBrainImage Interpretation, Computer-AssistedImage Processing, Computer-AssistedWaterWater7 TbrainEPI distortionsmotion correctionmulti-echonavigators

Identifiers

PMID35576128
PMCPMC9325528

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.