Evidence map›Paper›PMID 35576076›Full record

ArticleArchives of gynecology and obstetrics2023

Intrapartum ultrasound use in clinical practice as a predictor of delivery mode during prolonged second stage of labor.

Tamar Katzir, Yoav Brezinov, Ella Khairish, Shira Hadad, Edi Vaisbuch, Roni Levy

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of gynecology and obstetrics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.8field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 10 citations in OpenAlex.

  1. Intrapartum sonographic evaluation of fetal head descent in relation to maternal position: comparison between dorsal lithotomy and kneeling squat positions.Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2026
    Article
  2. Accurate evaluation of mode of delivery and labor progression with angle of progression: a prospective cross-sectional.Revista brasileira de ginecologia e obstetricia : revista da Federacao Brasileira das Sociedades de Ginecologia e Obstetricia · 2025
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Tamar KatzirDepartment of Obstetrics and Gynecology, Kaplan Medical Center, 76100, Rehovot, Israel.
Yoav BrezinovDepartment of Obstetrics and Gynecology, Kaplan Medical Center, 76100, Rehovot, Israel.
Ella KhairishDepartment of Obstetrics and Gynecology, Kaplan Medical Center, 76100, Rehovot, Israel.
Shira HadadDepartment of Obstetrics and Gynecology, Kaplan Medical Center, 76100, Rehovot, Israel.
Edi Vaisbuch *Department of Obstetrics and Gynecology, Kaplan Medical Center, 76100, Rehovot, Israel.
Roni Levy *Department of Obstetrics and Gynecology, Kaplan Medical Center, 76100, Rehovot, Israel. levyron67@gmail.com.ORCID http://orcid.org/0000-0003-2618-6328
Kaplan Medical Center · ILHebrew University of Jerusalem · IL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo determine the validity of intrapartum ultrasound (IPUS), and particularly the angle of progression (AOP), in predicting delivery mode when measured in real-life clinical practice among women with protracted second stages of labor.

methodsUsing electronic medical records, nulliparous women with a second stage of labor of ≥ 3 h ("prolonged") and a documented AOP measurement during the second stage were identified. The ability of a single AOP measurement in "prolonged" second stage to predict a vaginal delivery (VD) was assessed. Fetal head descent, measured by AOP change/h (calculated from serial measurements), was compared between women who delivered vaginally and those who had a cesarean delivery (CD) for arrest of descent.

resultsOf the 191 women who met the inclusion criteria, 62 (32.5%) delivered spontaneously, 96 (50.2%) had a vacuum extraction (VE) and 33 (17.3%) had a CD. The mean AOP was wider among women who had VD (spontaneous or VE) compared to those who had CD (153° ± 19 vs. 133° ± 17, p < 0.001). Wider AOPs were associated with higher rates of VD and an AOP ≥ 127° was associated with a VD rate of 88.6% (148/167). Among the 87 women who had more than one AOP measurement, the mean AOP change per hour was higher in the VD group than in the CD group (15.1° ± 11.4° vs. 6.2° ± 6.3°, p <  0.001).

conclusionUltrasound-assessed fetal head station in nulliparous women with a protracted second stage of labor can be an accurate and objective additive tool in predicting the mode and interval time to delivery in real-life clinical practice.

Indexed as

Labor Stage, SecondUltrasonography, PrenatalCesarean SectionDelivery, ObstetricFemaleHumansLabor PresentationPregnancyProspective StudiesAngle of progression (AOP)Intrapartum ultrasound (IPUS)Mode of deliveryNulliparousPregnancyProlonged second stage

Identifiers

PMID35576076
OpenAlexW4280499501

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.