Evidence map›Paper›PMID 35573968›Full record

ArticleFrontiers in pediatrics2022

Noninvasive Pediatric Liver Fibrosis Measurement: Two-Dimensional Shear Wave Elastography Compared With Transient Elastography.

Léa Chantal Tran, Delphine Ley, Gurvan Bourdon, Stéphanie Coopman, Héloïse Lerisson, Céline Tillaux, Hélène Béhal, Frédéric Gottrand, Madeleine Aumar

Abstract read
In one paragraph

Article in Frontiers in pediatrics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Léa Chantal TranUniversity of Lille, Inserm, CHU Lille, U1286 - INFINITE - Institute for Translational Research in Inflammation, Lille, France.
Delphine LeyUniversity of Lille, Inserm, CHU Lille, U1286 - INFINITE - Institute for Translational Research in Inflammation, Lille, France.
Gurvan BourdonDivision of Gastroenterology, Hepatology and Nutrition, Department of Paediatrics, Jeanne de Flandre Children's Hospital, CHU Lille and University of Lille, Lille, France.
Stéphanie CoopmanDivision of Gastroenterology, Hepatology and Nutrition, Department of Paediatrics, Jeanne de Flandre Children's Hospital, CHU Lille and University of Lille, Lille, France.
Héloïse LerissonDepartment of Paediatric Imaging, Jeanne de Flandre Children's Hospital, CHU Lille, Lille, France.
Céline TillauxDepartment of Paediatric Imaging, Jeanne de Flandre Children's Hospital, CHU Lille, Lille, France.
Hélène BéhalUniversity of Lille, CHU Lille, ULR 2694 - METRICS: Évaluation des Technologies de Santé et des Pratiques Médicales, Lille, France.
Frédéric GottrandUniversity of Lille, Inserm, CHU Lille, U1286 - INFINITE - Institute for Translational Research in Inflammation, Lille, France.
Madeleine AumarUniversity of Lille, Inserm, CHU Lille, U1286 - INFINITE - Institute for Translational Research in Inflammation, Lille, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: Although transient elastography (TE) is the primary noninvasive method for assessing liver fibrosis, its use remains to be validated in children. This study aims to evaluate the agreement between two-dimensional ultrasound shear wave elastography (2D-SWE) and TE to assess pediatric liver stiffness method. Methods: During the 18-month study, we prospectively included 101 consecutive children (median age: 8.5 years, range: 1 month to 17 years) who required TE for medical reasons, and in whom 2D-SWE measurement was performed within a 3-month follow-up during a routine ultrasound. Liver elasticity values were classified according to the Metavir score using published pediatric norms for TE and according to the manufacturer's reference values for 2D-SWE. The Spearman's correlation coefficient was used to assess the relationship between the elasticity measured by the two techniques. Concordance was described by the Bland-Altman method. Results: A strong correlation (rho = 0.70, Conclusion: Measurements of the liver stiffness using 2D-SWE and TE are strongly correlated. The moderate concordance between these techniques for assessing the liver fibrosis stage provides evidence against alternating between these methods during follow-up of patients with the chronic liver diseases.

Indexed as

cirrhosisliver diseasepediatricshear wave elastographyultrasound

Identifiers

PMID35573968
PMCPMC9095976

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.