Evidence map›Paper›PMID 35573231›Full record

ArticleFrontiers in bioengineering and biotechnology2022

Detection and Analysis of Bionic Motion Pose of Single Leg and Hip Joint Based on Random Process.

Peng Zhang, Seung-Soo Baek

Open access · goldAbstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 97% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 2 countries.

Peng ZhangSchool of Physical Education, Xinyang Normal University, Xinyang, China.
Seung-Soo BaekSchool of Physical Education, Sangmyung University, Seoul, Korea.
Sangmyung University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Based on the spectral representation method of random function and combined with memoryless nonlinear translation theory, this paper analyzes the transformation relationship between potential Gaussian random process and non-Gaussian random process, and successfully generates a stationary non-Gaussian random process that conforms to the target non-Gaussian random process. For the non-stationary non-Gaussian random process simulation, on the basis of the stationary Gaussian random process, the intensity non-stationary uniform modulation model is used to modulate it, and combined with the nonlinear translation theory, the non-stationary non-Gaussian random process conforming to the target non-Gaussian random process is obtained. Aiming at the single-leg bouncing model based on the flexible rotary hip joint, the stability of its bouncing motion under passive motion is studied, and the influence of the flexible hip rotary joint on the motion stability is analyzed by comparing the single-leg bouncing motion characteristics of the free rotary hip joint. Based on the inverse dynamic control of the air phase, the fixed point distribution of the single-leg bounce of the flexible rotary hip joint was improved, and the function of the flexible rotary hip joint in the energy conversion of the bouncing motion was studied by establishing the energy consumption evaluation function. The kinematic performance verification, dynamic performance verification, dynamic parameter identification verification, and modal experiment simulation analysis were carried out for the built experimental platform, and the comparison and analysis with its theoretical model were carried out. The results show that the theoretical motion trajectory of the test mobile platform is basically consistent with the actual motion trajectory in the X and Y directions, and there is a small error in the Z-axis direction, and the error is within an acceptable range, indicating that the experimental platform system can be used to simulate the human hip joint. There is a large error between the theoretical value of the driving torque calculated by the theoretical value of the dynamic parameters and the measured value, and the dynamic theoretical model cannot accurately predict the driving torque. The predicted value of the driving torque calculated by using the identification value of the dynamic parameters is in good agreement with the measured torque, and its confidence is increased by 10-16%, indicating that the dynamic parameter identification method in this paper has a high degree of confidence.

Indexed as

dynamic modelflexible swivel hip jointmotion pose detectionsingle leg and hip joint bionicsstochastic process