Evidence map›Paper›PMID 35572896›Full record

ArticleJournal of thoracic disease2022

Quality of transbronchial biopsy with large forceps compared to cryobiopsy: a randomized controlled, single blinded live animal study.

Wissam Abouzgheib, Osheen Abramian, Shuyue Ren, William Rafferty, Bhavi Patel, Nagendra Madisi, Paul Kannarkatt, Karl Lowa, Krystal Hunter, Ziad Boujaoude

Open access · diamondAbstract read
In one paragraph

Article in Journal of thoracic disease, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 52% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 1 country.

Wissam AbouzgheibDivision of Pulmonary and Interventional Pulmonary, Cooper University Hospital, Camden, NJ, USA.
Osheen AbramianDivision of Pulmonary and Interventional Pulmonary, Cooper University Hospital, Camden, NJ, USA.
Shuyue RenDepartment of Pathology, Cooper University Hospital, Camden, NJ, USA.
William RaffertyDepartment of Pathology, Cooper University Hospital, Camden, NJ, USA.
Bhavi PatelAtlantic Medical Group, Summit NJ, USA.
Nagendra MadisiDivision of Pulmonary and Critical Care Medicine, Albany Medical College, Albany, NY, USA.
Paul KannarkattDivision of Pulmonary and Interventional Pulmonary, Cooper University Hospital, Camden, NJ, USA.
Karl LowaDepartment of Anesthesiology, Cooper University Hospital, Camden, NJ, USA.
Krystal HunterCooper Research Institute, Cooper University Hospital, Camden, NJ, USA.
Ziad BoujaoudeDivision of Pulmonary and Interventional Pulmonary, Cooper University Hospital, Camden, NJ, USA.
Cooper University Hospital · USAlbany Medical Center Hospital · USSummit Medical Group (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Transbronchial forceps biopsy is the widely accepted modality for obtaining tissue specimens for the evaluation of unexplained lung parenchymal abnormalities. However, cryoprobe biopsy provides large specimen sizes and higher yield performance. Utilization of cryoprobe biopsy remains limited by its need to be performed under rigid bronchoscopy and subsequent required operator expertise. We evaluated whether a larger, 2.8 mm forceps could be utilized for parenchymal biopsies. A larger size would surrogate the cryoprobe's large sample size and forceps mechanism to obviate the need for rigid bronchoscopy and its requirement for removing the sample en bloc. Methods: This prospective, randomized controlled, single-blinded porcine study compared a 1.9 mm cryoprobe, a 2.4 mm cryoprobe, and a 2.8 mm forceps. Assessment of histopathologic quality, sample quality and surface area, attempts to retrieve specimen samples, fluoroscopy activation time, overall procedural time, and complications were compared. Results: Although cryoprobe yielded larger specimens, there was no statistical difference amongst all tools with respect to alveolar tissue surface area. There was bleeding on all cryoprobe biopsies. No bleeding was observed with forceps. Out of 32 potential combinations of interventions for bleeding control, 18 (56.3%) were made. There was no significant difference in sample quality between all three modalities. There was one pneumothorax in the forceps arm. Conclusions: Large forceps (LF) biopsy is a feasible technique while providing high diagnostic yield without the need for advanced therapeutic tools. Human studies are needed to further corroborate this technique.

Indexed as

cryobiopsyCryoprobe biopsyforceps biopsylung biopsy

Identifiers

PMID35572896
PMCPMC9096277
OpenAlexW4241408367

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.