Evidence map›Paper›PMID 35572421›Full record

ArticleJSES international2022

Tribocorrosion is common but mild in modular humeral components in shoulder arthroplasty: an implant retrieval analysis.

Christopher M Brusalis, Ryan R Thacher, Elexis Baral, Timothy M Wright, Lawrence V Gulotta, David M Dines, Russell F Warren, Michael C Fu, Samuel A Taylor

Open access · goldAbstract read
In one paragraph

Article in JSES international, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 51% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Christopher M BrusalisDepartment of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA.
Ryan R ThacherDepartment of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA.
Elexis BaralDepartment of Biomechanics, Hospital for Special Surgery, Weill Cornell Medicine of Cornell University, New York, NY, USA.
Timothy M WrightDepartment of Biomechanics, Hospital for Special Surgery, Weill Cornell Medicine of Cornell University, New York, NY, USA.
Lawrence V GulottaDepartment of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA.
David M DinesDepartment of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA.
Russell F WarrenDepartment of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA.
Michael C FuDepartment of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA.
Samuel A TaylorDepartment of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA.
Hospital for Special Surgery · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Wear and corrosion at the junctions of modular implants are increasingly recognized issues in the design of hip and knee arthroplasty prostheses, yet less is known about their significance in shoulder arthroplasty. Methods: A query of paired total shoulder implant specimens (eg, humeral head and stem components from the same patient) was performed using an institutional implant retrieval registry. Implants were examined under a stereomicroscope and evaluated for evidence of fretting and corrosion using the modified Goldberg scoring system. Available electronic medical records of included specimens were reviewed to report relevant clinical characteristics and identify potential associations with the presence of tribocorrosion. Results: Eighty-three paired total shoulder implant specimens, explanted at a single institution between 2013 and 2020, were analyzed. Corrosion was identified in 52% (43/83) of humeral head components and 40% (33/83) of humeral stem components. Fretting was identified in 29% (24/83) of humeral head components and 28% (23/83) of humeral stem components. Of the 56 paired implants for which clinical data were available, the duration of implantation (DOI) was less than 2 years in 29% of paired implants and greater than 5 years in 36% of implants. The presence of corrosion or fretting was not associated with DOI, a male humeral head taper, or periprosthetic infection as the indication for revision. Conclusion: Mild tribocorrosion was present in more than half of the retrieved humeral implant specimens. However, trunnionosis did not manifest as a clinical cause of revision surgery in our study.

Indexed as

CorrosionFrettingHumeral componentRetrievalRevisionShoulder arthroplasty

Identifiers

PMID35572421
PMCPMC9091787
OpenAlexW4213253512

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.