Evidence map›Paper›PMID 35571164›Full record

ArticleFrontiers in cardiovascular medicine2022

High-Resolution Free-Breathing Quantitative First-Pass Perfusion Cardiac MR Using Dual-Echo Dixon With Spatio-Temporal Acceleration.

Joao Tourais, Cian M Scannell, Torben Schneider, Ebraham Alskaf, Richard Crawley, Filippo Bosio, Javier Sanchez-Gonzalez, Mariya Doneva, Christophe Schülke, Jakob Meineke and 6 more

Open access · goldAbstract read
In one paragraph

Article in Frontiers in cardiovascular medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.2field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. High-resolution quantification of stress perfusion defects by cardiac magnetic resonance.European heart journal. Imaging methods and practice · 2024
    Article
  5. Cardiac MR: From Theory to Practice.Frontiers in cardiovascular medicine · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors at 7 institutions in 6 countries.

Joao TouraisDepartment of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands.
Cian M ScannellSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
Torben SchneiderPhilips Healthcare, Guildford, United Kingdom.
Ebraham AlskafSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
Richard CrawleySchool of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
Filippo BosioSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
Javier Sanchez-GonzalezPhilips Healthcare Iberia, Madrid, Spain.
Mariya DonevaPhilips Research, Hamburg, Germany.
Christophe SchülkePhilips Research, Hamburg, Germany.
Jakob MeinekePhilips Research, Hamburg, Germany.
Jochen KeuppPhilips Research, Hamburg, Germany.
Jouke SminkDepartment of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands.
Marcel BreeuwerDepartment of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands.
Amedeo ChiribiriSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
Markus HenningssonSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
Teresa CorreiaSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
King's College London · GBPhilips (Germany) · DEPhilips (Finland) · FIEindhoven University of Technology · NLLinköping University · SEPhilips (Spain) · ESPhilips (United Kingdom) · GB

Funding

Wellcome Trust 203148/Z/16/Z
6 · The paper itself

Abstract

Introduction: To develop and test the feasibility of free-breathing (FB), high-resolution quantitative first-pass perfusion cardiac MR (FPP-CMR) using dual-echo Dixon (FOSTERS; Fat-water separation for mOtion-corrected Spatio-TEmporally accelerated myocardial peRfuSion). Materials and Methods: FOSTERS was performed in FB using a dual-saturation single-bolus acquisition with dual-echo Dixon and a dynamically variable Cartesian k-t undersampling (8-fold) approach, with low-rank and sparsity constrained reconstruction, to achieve high-resolution FPP-CMR images. FOSTERS also included automatic in-plane motion estimation and T Results: FOSTERS produced high-quality images without dark-rim and with reduced motion-related artifacts, using an 8x accelerated FB acquisition. FOSTERS and standard BH FPP-CMR exhibited excellent IQ with an average score of 3.5 ± 0.6 and 3.4 ± 0.6 (no statistical difference, Discussion: FOSTERS enabled high-resolution FB FPP-CMR with MBF quantification. Combining motion correction with a low-rank and sparsity-constrained reconstruction results in excellent image quality.

Indexed as

Dixonfree-breathinghigh-resolutionmotion correctionmyocardial perfusionquantitative myocardial blood flow

Identifiers

PMID35571164
PMCPMC9099052
OpenAlexW4225155280

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.