ArticleZhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery2022
[Accuracy of key point matrix technology based contactless automatic measurement for joint motion of hand].
Article in Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- An Intelligent Hand-Assisted Diagnosis System Based on Information Fusion.Sensors (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective: To validate the use of key point matrix technology based contactless automatic measurement for evaluation of joint motion of hand. Methods: Thirty-three volunteers were enrolled to evaluate the extension and flexion of hand joints between May 2021 and November 2021. There were 20 males and 13 females, the age ranged from 16 to 70 years with an average of 30.2 years. The extension angles of 14 joints of 5 fingers (including hyperextension) and the flexion angles of 12 joints of 4 fingers (excluding thumb) of volunteers were measured by key point matrix technology and manual goniometer, respectively. Then 5 participants and repeated measurement experiment were employed to test the system repeatability and accuracy; 28 participants and paired measurement experiment were employed to test the system accuracy. Results: The average repeatability of finger joint motion measured by the key point matrix technology was 1.801° (extension) and 7.823° (flexion), respectively. Compared with manual measurement, the average differences of each finger joint measured by the key point matrix technology were 3.225° in extension and 14.145° in flexion, respectively. The key point matrix technology based contactless automatic evaluation system offered excellent consistency with the manual goniometers ( Conclusion: The key point matrix technology based contactless automatic evaluation provides sufficient measurement repeatability and accuracy in evaluation for the joint motion of hand.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.