Evidence map›Paper›PMID 35570398›Full record

ArticleJournal of applied clinical medical physics2022

Matched linac stereotactic radiotherapy: An assessment of delivery similarity and distributive patient-specific quality assurance feasibility.

Simon K Goodall, Leon Dunn, Jonathan Dunning, Luis Muñoz, Pejman Rowshanfarzad, Martin A Ebert

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.7field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Simon K GoodallSchool of Physics, Mathematics, and Computing, Faculty of Engineering and Mathematical Sciences, University of Western Australia, Crawley, Western Australia, Australia.
Leon DunnGenesisCare, Fitzroy, Victoria, Australia.
Jonathan DunningGenesisCare, Fitzroy, Victoria, Australia.
Luis MuñozGenesisCare, Bedford Park, South Australia, Australia.
Pejman RowshanfarzadSchool of Physics, Mathematics, and Computing, Faculty of Engineering and Mathematical Sciences, University of Western Australia, Crawley, Western Australia, Australia.
Martin A EbertSchool of Physics, Mathematics, and Computing, Faculty of Engineering and Mathematical Sciences, University of Western Australia, Crawley, Western Australia, Australia.
Genesis HealthCare · USUniversity of Western Australia · AUSir Charles Gairdner Hospital · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Matching multiple linacs to common baseline data allows patients to be treated, and patient-specific quality assurance (PSQA) to be completed on any linac. Stereotactic body radiotherapy (SBRT) requires higher levels of accuracy and quality assurance than routine radiotherapy. The achieved linac matching must therefore be evaluated before distributive treatment or PSQA models can be implemented safely. This investigation aimed to propose metrics for defining linacs to be matched for SBRT deliveries, assess 12 linacs against these criteria, and determine if a distributive PSQA model could be implemented by reviewing the rates of false PSQA results. Ten SBRT spine plans were delivered by 12 matched Elekta linacs and measured using one of seven SRS MapCHECK devices. For gamma criteria of (3%, 2 mm), 96.9% of equivalent location detectors, showed a range of gamma ≤ 1.0 and 99.9% showed a standard deviation of ≤ 0.5. For criteria of (3%,1 mm) and (2%,1 mm), these ranges decreased to 92.1% and 80.2% while the standard deviations decreased to 99.3% and 95.7%, respectively. The dose differences showed that 43.6%, 82.7%, and 91.4% of detectors had a dose range of ≤ 3.0%, ≤ 5.0%, and ≤ 6.0%, respectively. Standard deviations of dose differences were 1.5%, 2.5%, and 3.0% for 94.1%, 98.3%, and 99.5% of detectors, respectively. For the fleet of linacs, distributive PSQA yielded false results for 0.0%, 17.7%, and 33.0% of plans, equivalent to 1.2%, 3.5%, and 9.4% of detectors when using gamma criteria of (3%,2 mm), (3%,1 mm), or (2%,1 mm), respectively. These linacs could be considered matched for SBRT treatments and implement a distributive PSQA model when gamma analysis was completed with a criterion of (3%, 2 mm). For stricter criterion of (3%,1 mm) or (2%,1 mm), they did not meet the proposed metrics.

Indexed as

RadiosurgeryRadiotherapy, Intensity-ModulatedFeasibility StudiesHumansPhantoms, ImagingRadiotherapy DosageRadiotherapy Planning, Computer-Assistedbeam-matchingdistributive PSQAmatchSBRTVMAT

Identifiers

PMID35570398
PMCPMC9680571
OpenAlexW4280496890

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.