ArticleBMC chemistry2022
Development and validation of a HPLC-UV method for methadone hydrochloride quantification in a new oral solution with preservatives to be implemented in physicochemical stability studies.
Article in BMC chemistry, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Persistence in the Methadone Maintenance Program and Its Relationship with the Medication Regimen Complexity Index in Opioid-Dependent Patients.Pharmaceuticals (Basel, Switzerland) · 2024Article
- Physicochemical and Microbiological Stability of Two Oral Solutions of Methadone Hydrochloride 10 mg/mL.Molecules (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe Pharmacy Service of the Infanta Leonor University Hospital acquires, compounds, distributes and dispenses more than 3000 L of methadone oral solution to Drug Addiction Patients Centers per year. Our purpose is to develop and validate an improved high performance liquid chromatography (HPLC) method to quantify methadone hydrochloride in a new oral solution with methylhydroxybenzoate (methylparaben) and propylhydroxybenzoate (propylparaben) to be implemented in physicochemical stability studies that allow to provide more information and even to increase the beyond-use date.
methodsA HPLC-Agilent
resultsChromatographic conditions were: flow rate 1.6 mL/min; mobile phase 55% acetonitrile and 45% sodium phosphate 25 mM (pH = 10); injection volume was 5 µL. The column was a Waters-XTerra™ RP18, maintained at 40 °C. DAD was λ = 254 nm. Retention times for methadone, methylparaben and propylparaben were 4.34, 0.70 and 0.88 min respectively. The method was linear (y = 284.3x - 97.8, r = 0.996). Instrumental precision was 0.33% for standards (n = 10); intra-assay precision 0.53% (n = 6) and inter-assay precision 1.95% (n = 12). The relative standard deviation percentage for accuracy was 1.28%. The recovery percentage was 101.5 ± 1.5%. LQ and LD were 2.18 µg/mL and 2.0 µg/mL respectively. The most destabilizing conditions were oxidizing and alkaline. The chromatograms confirmed no interference with the methadone signal.
conclusionsThe HPLC method has proved to be valid and reproducible for methadone quantification in a new oral solution with methylparaben and propylparaben. This assay is a rapid, simple and reliable technique that can be used in daily analysis and physicochemical stability studies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.