Evidence map›Paper›PMID 35566551›Full record

ArticleJournal of clinical medicine2022

Comparing the Time-Dependent Evolution of Microcirculation in Gracilis vs. ALT Flaps Using Laser-Doppler Flowmetry and Tissue-Spectrometry.

Nicholas Moellhoff, Paul I Heidekrueger, Konstantin Frank, Svenja Pistek, Verena Alt, Riccardo E Giunta, Denis Ehrl

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.6field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Free flaps monitoring by Laser-Doppler Flowmetry in head and neck surgery.Acta otorhinolaryngologica Italica : organo ufficiale della Societa italiana di otorinolaringologia e chirurgia cervico-facciale · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Nicholas MoellhoffDivision of Hand, Plastic and Aesthetic Surgery, University Hospital, Ludwig Maximilian University of Munich, 81377 Munich, Germany.
Paul I HeidekruegerCentre of Plastic, Aesthetic, Hand and Reconstructive Surgery, University of Regensburg, 93053 Regensburg, Germany.ORCID 0000-0002-4656-3808
Konstantin FrankDivision of Hand, Plastic and Aesthetic Surgery, University Hospital, Ludwig Maximilian University of Munich, 81377 Munich, Germany.
Svenja PistekDivision of Hand, Plastic and Aesthetic Surgery, University Hospital, Ludwig Maximilian University of Munich, 81377 Munich, Germany.
Verena AltDivision of Hand, Plastic and Aesthetic Surgery, University Hospital, Ludwig Maximilian University of Munich, 81377 Munich, Germany.
Riccardo E GiuntaDivision of Hand, Plastic and Aesthetic Surgery, University Hospital, Ludwig Maximilian University of Munich, 81377 Munich, Germany.
Denis EhrlDivision of Hand, Plastic and Aesthetic Surgery, University Hospital, Ludwig Maximilian University of Munich, 81377 Munich, Germany.
Ludwig-Maximilians-Universität München · DEUniversity of Regensburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Postoperative free flap monitoring is considered a key component of care after microsurgical reconstruction. To achieve successful flap salvage after surgical revision, early recognition of vascular compromise is required. The aim of this study was to assess and compare the time-dependent evolution of microcirculation in gracilis muscle (GM) and anterolateral thigh (ALT) flaps. This study included continuous measurements of blood flow (flow), hemoglobin oxygenation (SO2) and the relative amount of hemoglobin (rHb) using laser-doppler flowmetry and tissue-spectrometry (O2C, LEA Medizintechnik, Gießen, Germany) over a time-period of 72 h. Microcirculation was assessed in a total of 66 viable free flaps (GM n = 40; ALT n = 26). A statistically significant positive correlation between time post-anastomosis and microvascular flow was found for both GM and ALT flaps with rs = 0.384 (p < 0.001) and rs = 0.178 (p = 0.015), respectively. No significant positive or negative correlations between time post-anastomosis and SO2 were found for both GM and ALT flaps with rs = 0.052 (p = 0.387) and rs = −0.018 (p = 0.805), respectively. Overall, a significant negative correlation between time post-anastomosis and rHb was found for GM flaps with rs = −0.140 (p = 0.019). For ALT flaps, no significant positive or negative correlation was found with rs = −0.011 (p = 0.887). Microcirculation differs in different flap entities, and surgeons should be aware of these differences in order to correctly evaluate and classify the values of flow, SO2 and rHb obtained when using the O2C device for postoperative monitoring.

Indexed as

anastomosisfree flapmicrosurgerymicrovascular flowO2C

Identifiers

PMID35566551
PMCPMC9099565
OpenAlexW4224979679

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.