Evidence map›Paper›PMID 35566400›Full record

ArticleJournal of clinical medicine2022

Medium- to Long-Term Outcomes after Reverse Total Shoulder Arthroplasty with a Standard Long Stem.

Matthias Bülhoff, Felix Zeifang, Caroline Welters, Tobias Renkawitz, Marcus Schiltenwolf, Anna-K Tross

Abstract read
In one paragraph

Article in Journal of clinical medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Rotator cuff tears.Nature reviews. Disease primers · 2024
    Review
  5. Review
  6. Mid-term outcomes following reverse total shoulder arthroplasty.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2024
    Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Matthias BülhoffClinic for Orthopaedic Surgery, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany.
Felix ZeifangEthianum Clinic Heidelberg, Voßstraße 6, 69115 Heidelberg, Germany.
Caroline WeltersClinic for Dermatology, Munich Municipal Hospital Group, Thalkirchnerstrasse 48, 80337 Munich, Germany.
Tobias RenkawitzClinic for Orthopaedic Surgery, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany.
Marcus SchiltenwolfClinic for Orthopaedic Surgery, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany.ORCID 0000-0003-0835-4172
Anna-K TrossClinic for Orthopaedic Surgery, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany.

Funding

Deutsche Arthrose-Hilfe e.V P385-A326-Ewerbeck-EP11-bülh1-schulter-en-II-10k-2017-19
6 · The paper itself

Abstract

Background: Long-term clinical and radiographic outcome data after standard cemented long-stem reverse shoulder arthroplasty (RSA) remain underreported. The aim of this study is to report on medium- to long-term data of patients over 60 years of age. Methods: The same type of RSA (Aequalis Reverse II, Memphis, TN, USA) was implanted in 27 patients with a mean age of 73 years (range 61−84). Indications for RSA were cuff tear arthropathy (CTA) in 25 cases and osteoarthritis (OA) in two cases. Pre- and postoperative Constant Score was assessed and component loosening, polyethylene wear, scapular notching and revision rates were recorded at a mean clinical follow-up (FU) of 127.6 months (SD ± 33.7; range 83−185). Results: The mean-adjusted CS (aCS) improved from 30.0 (range 10−59) to 95.0 (range 33−141) points (p < 0.001). Glenoid loosening was found in two (9.1%) and stem loosening was found in three (13.6%) cases. Polyethylene wear was observed in four (18.2%) cases. Scapular notching appeared in 15 (68.2%) cases but was not associated with poor aCS (p = 0.423), high levels of pain (p = 0.798) or external rotation (p = 0.229). Revision surgery was necessary in three (11.1%) cases. Conclusions: RSA with a cemented standard long stem leads to improvement in forward elevation, abduction and pain after a mean FU of 10 years. However, external rotation does not improve with this prosthetic design. Moreover, scapular notching is observed in the majority of cases, and revision rates (11.1%) as well as humeral loosening rates (13.6%) remain a concern. Level of evidence: Level 4, retrospective cohort study.

Indexed as

glenoid looseninghumeral looseningpolyethylene wearreverse arthroplastyscapular notchingshoulder

Identifiers

PMID35566400
PMCPMC9103013

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked