Evidence map›Paper›PMID 35563064›Full record

ArticleInternational journal of molecular sciences2022

Enabling Coarse X-ray Fluorescence Imaging Scans with Enlarged Synchrotron Beam by Means of Mosaic Crystal Defocusing Optics.

Jonas Baumann, Christian Körnig, Theresa Staufer, Christopher Schlesiger, Oliver Schmutzler, Florian Grüner, Wolfgang Malzer, Birgit Kanngießer

Abstract read
In one paragraph

Article in International journal of molecular sciences, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jonas BaumannAnalytical X-ray Physics, Technical University of Berlin, Hardenbergstr. 36, 10623 Berlin, Germany.ORCID 0000-0002-1085-9527
Christian KörnigFachbereich Physik, Universitö at Hamburg and Center for Free-Electron Laser Science (CFEL), Luruper Chaussee 149, 22761 Hamburg, Germany.
Theresa StauferFachbereich Physik, Universitö at Hamburg and Center for Free-Electron Laser Science (CFEL), Luruper Chaussee 149, 22761 Hamburg, Germany.
Christopher SchlesigerAnalytical X-ray Physics, Technical University of Berlin, Hardenbergstr. 36, 10623 Berlin, Germany.
Oliver SchmutzlerFachbereich Physik, Universitö at Hamburg and Center for Free-Electron Laser Science (CFEL), Luruper Chaussee 149, 22761 Hamburg, Germany.
Florian GrünerFachbereich Physik, Universitö at Hamburg and Center for Free-Electron Laser Science (CFEL), Luruper Chaussee 149, 22761 Hamburg, Germany.
Wolfgang MalzerAnalytical X-ray Physics, Technical University of Berlin, Hardenbergstr. 36, 10623 Berlin, Germany.
Birgit KanngießerAnalytical X-ray Physics, Technical University of Berlin, Hardenbergstr. 36, 10623 Berlin, Germany.

Funding

Federal Ministry of Education and Research 05K19KT1
6 · The paper itself

Abstract

Trace elements, functionalized nanoparticles and labeled entities can be localized with sub-mm spatial resolution by X-ray fluorescence imaging (XFI). Here, small animals are raster scanned with a pencil-like synchrotron beam of high energy and low divergence and the X-ray fluorescence is recorded with an energy-dispersive detector. The ability to first perform coarse scans to identify regions of interest, followed by a close-up with a sub-mm X-ray beam is desirable, because overall measurement time and X-ray dose absorbed by the (biological) specimen can thus be minimized. However, the size of X-ray beams at synchrotron beamlines is usually strongly dependent on the actual beamline setup and can only be adapted within specific pre-defined limits. Especially, large synchrotron beams are non-trivial to generate. Here, we present the concept of graphite-based, convex reflection optics for the one-dimensional enlargement of a 1 mm wide synchrotron beam by a factor of 5 to 10 within a 1 m distance. Four different optics are tested and characterized and their reflection properties compared to ray tracing simulations. The general shape and size of the measured reflection profiles agree with expectations. Enhancements with respect to homogeneity and efficiency can be expected with improved optics manufacturing. A mouse phantom is used for a proof-of-principle XFI experiment demonstrating the applicability of coarse and fine scans with the suggested optics design.

Indexed as

Optics and PhotonicsSynchrotronsAnimalsMiceOptical ImagingPhantoms, ImagingX-Rayscoarse scanHOPG/HAPG opticssynchrotron beamX-ray fluorescence imaging

Identifiers

PMID35563064
PMCPMC9104365

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.