Evidence map›Paper›PMID 35559649›Full record

ReviewACS sensors2022

Biosensors Integration in Blood-Brain Barrier-on-a-Chip: Emerging Platform for Monitoring Neurodegenerative Diseases.

Mònica Mir, Sujey Palma-Florez, Anna Lagunas, Maria José López-Martínez, Josep Samitier

Open access · hybridAbstract readReview
In one paragraph

Review in ACS sensors, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed
4.4field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed, 56 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Review
  6. Review
  7. Review
  8. Review
  9. Recent advances in electrochemiluminescence sensing for in vitro cell analysis: a review.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2025
    Review
  10. Review
  11. Article
  12. Review
  13. Review
  14. Review
  15. Review
  16. Review
  17. Article
  18. Towards Novel BiomimeticBioengineering (Basel, Switzerland) · 2023
    Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Mònica MirBiomedical Research Networking Center in Bioengineering, Biomaterials, and Nanomedicine (CIBER-BBN) Monforte de Lemos 3-5, Pabellón 11, 28029 Madrid, Spain.ORCID 0000-0002-1490-8373
Sujey Palma-FlorezNanobioengineering Group, Institute for Bioengineering of Catalonia (IBEC), Barcelona Institute of Science and Technology (BIST), 12 Baldiri Reixac 15-21, Barcelona 08028, Spain.
Anna LagunasBiomedical Research Networking Center in Bioengineering, Biomaterials, and Nanomedicine (CIBER-BBN) Monforte de Lemos 3-5, Pabellón 11, 28029 Madrid, Spain.ORCID 0000-0002-0936-3401
Maria José López-MartínezBiomedical Research Networking Center in Bioengineering, Biomaterials, and Nanomedicine (CIBER-BBN) Monforte de Lemos 3-5, Pabellón 11, 28029 Madrid, Spain.
Josep SamitierBiomedical Research Networking Center in Bioengineering, Biomaterials, and Nanomedicine (CIBER-BBN) Monforte de Lemos 3-5, Pabellón 11, 28029 Madrid, Spain.
Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine · ESInstitute for Bioengineering of Catalonia · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Over the most recent decades, the development of new biological platforms to study disease progression and drug efficacy has been of great interest due to the high increase in the rate of neurodegenerative diseases (NDDs). Therefore, blood-brain barrier (BBB) as an organ-on-a-chip (OoC) platform to mimic brain-barrier performance could offer a deeper understanding of NDDs as well as a very valuable tool for drug permeability testing for new treatments. A very attractive improvement of BBB-oC technology is the integration of detection systems to provide continuous monitoring of biomarkers in real time and a fully automated analysis of drug permeably, rendering more efficient platforms for commercialization. In this Perspective, an overview of the main BBB-oC configurations is introduced and a critical vision of the BBB-oC platforms integrating electronic read out systems is detailed, indicating the strengths and weaknesses of current devices, proposing the great potential for biosensors integration in BBB-oC. In this direction, we name potential biomarkers to monitor the evolution of NDDs related to the BBB and/or drug cytotoxicity using biosensor technology in BBB-oC.

Indexed as

Biosensing TechniquesNeurodegenerative DiseasesBlood-Brain BarrierBrainHumansLab-On-A-Chip Devicesbiosensorsblood−brain barrier (BBB)neurodegenerative diseases (NDDs)organ-on-a-chip (OoC)transepithelial/transendothelial electrical resistance (TEER)

Identifiers

PMID35559649
PMCPMC9150172
OpenAlexW4280524207

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.