Can magnetisation transfer magnetic resonance imaging help for the follow-up of synthetic hernia composite meshes fate? A pilot study.

Florence Franconi, Olivier Lefranc, Amandine Radlovic, Laurent Lemaire

Abstract read
PubMed Publisher
In one paragraph

Article in Magma (New York, N.Y.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 48% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Florence FranconiUNIV ANGERS, PRISM-Plateforme de Recherche en Imagerie et Spectroscopie Multimodales, 4 rue Larrey, 49933, Angers, France.ORCID http://orcid.org/0000-0001-6725-0803
Olivier LefrancSOFRADIM Production, 116 avenue du Formans, 01600, Trevoux, France.
Amandine RadlovicSOFRADIM Production, 116 avenue du Formans, 01600, Trevoux, France.
Laurent LemaireUNIV ANGERS, PRISM-Plateforme de Recherche en Imagerie et Spectroscopie Multimodales, 4 rue Larrey, 49933, Angers, France. laurent.lemaire@univ-angers.fr.ORCID http://orcid.org/0000-0002-1308-9345
Centre National de la Recherche Scientifique · FRSofradir (France) · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aims at evaluating the non-invasive Magnetic Resonance Imaging (MRI) technic to visualize a synthetic composite hernia mesh using a rodent model and to document the integration of this device over 4 months.

methodsUncoated polyethylene terephthalate mesh and synthetic composite mesh-faced on the visceral side with a chemically engineered layer of copolymer of glycolide, caprolactone, trimethylene carbonate, and lactide to minimize tissue attachment-were placed intraperitoneally in rats, facing the caecum previously scraped to promote petechial bleeding and subsequent adhesions. Meshes fate follow-up was performed 4, 10, and 16-weeks post-implantation using a rodent dedicated high field MRI. Magnetization transfer (MT) images were acquired, associated with pneumoperitonealMRI performed after intraperitoneal injection of 8 mL gas to induce mechanical stress on the abdominal wall.

resultsUncoated meshes were clearly visible using both T2-weighted and MT imaging during the whole study while composite meshes conspicuity was not so evident on T2-weighted MRI and could be improved using MT imaging. Adhesions and collagen infiltration were massive for the uncoated meshes as expected. On the contrary, composite meshes showed very limited adhesion, and, if any, occurring at the edge of the mesh, starting at the fixation points.

conclusionsMagnetization transfer imaging allows to detect mesh integration and, associated with pneumoperitoneum, was able to probe the effective minimizing effect of the synthetic polymeric barrier on visceral attachments. However, magnetization transfer imaging could not unambiguously allow the visualization of the mesh through the polymeric barrier.

Indexed as

Hernia, VentralAnimalsCollagenFollow-Up StudiesMagnetic Resonance ImagingPilot ProjectsPolyethylene TerephthalatesRatsSurgical MeshTissue AdhesionsCollagenPolyethylene TerephthalatesMagnetization transferMeshMRIPneumoperitoneumVentral hernia repairVisceral attachment

Identifiers

PMID35552915
OpenAlexW4280579277

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.