ArticlePloS one2022
Dynamic response and low voltage ride-through enhancement of brushless double-fed induction generator using Salp swarm optimization algorithm.
Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 12 citations in OpenAlex.
- A new approach for improving dynamic fault ride through capability of gridctied based wind turbines.Scientific reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 6 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A brushless double-fed induction generator (BDFIG) has shown tremendous success in wind turbines due to its robust brushless design, smooth operation, and variable speed characteristics. However, the research regarding controlling of machine during low voltage ride through (LVRT) need greater attention as it may cause total disconnection of machine. In addition, the BDFIG based wind turbines must be capable of providing controlled amount of reactive power to the grid as per modern grid code requirements. Also, a suitable dynamic response of machine during both normal and fault conditions needs to be ensured. This paper, as such, attempts to provide reactive power to the grid by analytically calculating the decaying flux and developing a rotor side converter control scheme accordingly. Furthermore, the dynamic response and LVRT capability of the BDFIG is enhanced by using one of the very intelligent optimization algorithms called the Salp Swarm Algorithm (SSA). To prove the efficacy of the proposed control scheme, its performance is compared with that of the particle swan optimization (PSO) based controller in terms of limiting the fault current, regulating active and reactive power, and maintaining the stable operation of the power system under identical operating conditions. The simulation results show that the proposed control scheme significantly improves the dynamic response and LVRT capability of the developed BDFIG based wind energy conversion system; thus proves its essence and efficacy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.