Evidence map›Paper›PMID 35550626›Full record

ArticlePloS one2022

Testing and validation of reciprocating positive displacement pump for benchtop pulsating flow model of cerebrospinal fluid production and other physiologic systems.

Ahmad Faryami, Adam Menkara, Daniel Viar, Carolyn A Harris

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.9field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 10 citations in OpenAlex.

  1. Quantitative and qualitative investigation of shunt failure in anFrontiers in bioengineering and biotechnology · 2025
    Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Ahmad FaryamiDepartment of Biomedical Engineering, Wayne State University, Detroit, MI, United States of America.ORCID 0000-0001-5117-6258
Adam MenkaraDepartment of Biomedical Engineering, Wayne State University, Detroit, MI, United States of America.
Daniel ViarDepartment of Computer Science and Engineering, University of Toledo, Toledo, Ohio, United States of America.
Carolyn A HarrisWayne State University Dept. of Chemical Engineering and Materials Science, Detroit, MI, United States of America.ORCID 0000-0002-9700-7457
Wayne State University · USUniversity of Toledo · US

Funding

Investigating the source and the action behind shunt obstruction in the treatment of pediatric hydrocephalusR01NS094570 · NINDS · WAYNE STATE UNIVERSITY · PI Carolyn A Harris · 2016 to 2026
$4.2M
NINDS NIH HHS R01 NS094570
6 · The paper itself

Abstract

backgroundThe flow of physiologic fluids through organs and organs systems is an integral component of their function. The complex fluid dynamics in many organ systems are still not completely understood, and in-vivo measurements of flow rates and pressure provide a testament to the complexity of each flow system. Variability in in-vivo measurements and the lack of control over flow characteristics leave a lot to be desired for testing and evaluation of current modes of treatments as well as future innovations. In-vitro models are particularly ideal for studying neurological conditions such as hydrocephalus due to their complex pathophysiology and interactions with therapeutic measures. The following aims to present the reciprocating positive displacement pump, capable of inducing pulsating flow of a defined volume at a controlled beat rate and amplitude. While the other fluidic applications of the pump are currently under investigation, this study was focused on simulating the pulsating cerebrospinal fluid production across profiles with varying parameters.

methodsPumps were manufactured using 3D printed and injection molded parts. The pumps were powered by an Arduino-based board and proprietary software that controls the linear motion of the pumps to achieve the specified output rate at the desired pulsation rate and amplitude. A range of 0.01 [Formula: see text] to 0.7 [Formula: see text] was tested to evaluate the versatility of the pumps. The accuracy and precision of the pumps' output were evaluated by obtaining a total of 150 one-minute weight measurements of degassed deionized water per output rate across 15 pump channels. In addition, nine experiments were performed to evaluate the pumps' control over pulsation rate and amplitude.

resultsVolumetric analysis of a total of 1200 readings determined that the pumps achieved the target output volume rate with a mean absolute error of -0.001034283 [Formula: see text] across the specified domain. It was also determined that the pumps can maintain pulsatile flow at a user-specified beat rate and amplitude.

conclusionThe validation of this reciprocating positive displacement pump system allows for the future validation of novel designs to components used to treat hydrocephalus and other physiologic models involving pulsatile flow. Based on the promising results of these experiments at simulating pulsatile CSF flow, a benchtop model of human CSF production and distribution could be achieved through the incorporation of a chamber system and a compliance component.

Indexed as

HydrocephalusHydrodynamicsHumansPulsatile Flow

Identifiers

PMID35550626
PMCPMC9098063
OpenAlexW4280631750

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.