Evidence map›Paper›PMID 35549522›Full record

ArticleJournal of diabetes science and technology2024

Laboratory Protocol and Pilot Results for Dynamic Interference Testing of Continuous Glucose Monitoring Sensors.

Andreas Pfützner, Hendrick Jensch, Christopher Cardinal, Geetham Srikanthamoorthy, Eric Riehn, Nicole Thomé

Open access · bronzeAbstract read
In one paragraph

Article in Journal of diabetes science and technology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 1 pooled it
2.5field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 1 synthesis or guideline pooled it, 18 citations in OpenAlex.

  1. Guideline
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
  10. Article
  11. Review
  12. Article
  13. Article
  14. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 2 countries.

Andreas PfütznerPfützner Science & Health Institute, Mainz, Germany.ORCID 0000-0003-2385-0887
Hendrick JenschPfützner Science & Health Institute, Mainz, Germany.
Christopher CardinalPfützner Science & Health Institute, Mainz, Germany.
Geetham SrikanthamoorthyPfützner Science & Health Institute, Mainz, Germany.
Eric RiehnPfützner Science & Health Institute, Mainz, Germany.
Nicole ThoméPfützner Science & Health Institute, Mainz, Germany.
TH Bingen University of Applied Sciences · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTesting the potential influence of interfering substances on the measurement performance of needle sensors for continuous glucose monitoring (CGM) is a challenging task. For proper function, the sensors need an almost stable fluidic environment. Previously published in vitro interference experiments were measuring under static concentration conditons. Our experimental setup allows for interference testing with dynamic changes of the interferent concentrations.

methodsWe designed a macrofluidic test stand that is fueled by several high-pressure liquid chromatography (HPLC) pumps generating programmable glucose and/or interferent gradients in phosphate-buffered saline (PBS). After optimizing experimental parameters (channel dimensions, temperature, flow rates, gradient slopes, buffer, pH etc.), we validated the setup using Dexcom G6 (G6) and Freestyle Libre 2 (L2) sensors with/without interferents, and using YSI 2300 Stat plus as the reference glucose device at room temperature.

resultsBoth sensors tracked the programmed glucose changes. After calibration, G6 results closely matched glucose reference readings, while L2 routinely showed ~50% to 60% lower readings, most likely because of the factory-based calibration and temperature compensation. Gradients of maltose, acetaminophen, and xylose were employed to further validate the setup. As expected, both sensors were not affected by maltose. We confirmed previous findings regarding susceptibility of G6 readings to acetaminophen and L2 readings to xylose. Signals from both sensors are influenced by temperature in a linear fashion.

conclusionsOur experimental in vitro setup and protocol may provide a useful method to dynamically test CGM sensors for interfering substances. This may help to improve the accuracy of future CGM sensor generations.

Indexed as

Blood GlucoseDiabetes Mellitus, Type 1AcetaminophenBlood Glucose Self-MonitoringContinuous Glucose MonitoringGlucoseHumansMaltoseReproducibility of ResultsXyloseAcetaminophenBlood GlucoseGlucoseMaltoseXyloseCGMcocktail interferencecontinuous glucose monitoringdynamic interferenceinterference testingin vitro test protocol

Identifiers

PMID35549522
PMCPMC10899833
OpenAlexW4280533815

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked