ArticleJournal of diabetes science and technology2024
Laboratory Protocol and Pilot Results for Dynamic Interference Testing of Continuous Glucose Monitoring Sensors.
Article in Journal of diabetes science and technology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 1 synthesis or guideline pooled it, 18 citations in OpenAlex.
- International Society for Pediatric and Adolescent Diabetes Clinical Practice Consensus Guidelines 2024 Diabetes Technologies: Glucose Monitoring.Hormone research in paediatrics · 2024Guideline
- Implementing ADA 2026 diabetes technology recommendations: opportunities and challenges for quality improvement in real-world care.BMJ open quality · 2026Article
- 7. Diabetes Technology: Standards of Care in Diabetes-2026.Diabetes care · 2026Review
- Toward Trustworthy Diabetes Technologies: A Dynamic Platform for Safety and Security Evaluation.BME frontiers · 2026Article
- Interference of Intravenous Acetaminophen with Continuous Glucose Monitoring System.JMA journal · 2025Article
- Dynamic Interference Testing-Unexpected Results Obtained with the Abbott Libre 2 and Dexcom G6 Continuous Glucose Monitoring Devices.Sensors (Basel, Switzerland) · 2025Article
- System Accuracy and Interference Evaluation of a New Glucose Dehydrogenase-Based Blood Glucose Meter for Patient Self-Testing.Journal of diabetes science and technology · 2025Article
- 7. Diabetes Technology: Standards of Care in Diabetes-2025.Diabetes care · 2025Review
- Drug Interference in Self-Monitoring of Blood Glucose and the Impact on Patient Safety: We Can Only Guard Against What We Are Looking for.Journal of diabetes science and technology · 2024Review
- Perceptions of Continuous Glucose Monitoring Systems in the T1D Exchange Diabetes Registry: Satisfaction, Concerns, and Areas for Future Improvement.Clinical diabetes : a publication of the American Diabetes Association · 2024Article
- 7. Diabetes Technology: Standards of Care in Diabetes-2024.Diabetes care · 2024Review
- A Consensus Statement for Continuous Glucose Monitoring Metrics for Inpatient Clinical Trials.Journal of diabetes science and technology · 2023Article
- Miniaturization of an Osmotic Pressure-Based Glucose Sensor for Continuous Intraperitoneal and Subcutaneous Glucose Monitoring by Means of Nanotechnology.Sensors (Basel, Switzerland) · 2023Article
- 7. Diabetes Technology: Standards of Care in Diabetes-2023.Diabetes care · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTesting the potential influence of interfering substances on the measurement performance of needle sensors for continuous glucose monitoring (CGM) is a challenging task. For proper function, the sensors need an almost stable fluidic environment. Previously published in vitro interference experiments were measuring under static concentration conditons. Our experimental setup allows for interference testing with dynamic changes of the interferent concentrations.
methodsWe designed a macrofluidic test stand that is fueled by several high-pressure liquid chromatography (HPLC) pumps generating programmable glucose and/or interferent gradients in phosphate-buffered saline (PBS). After optimizing experimental parameters (channel dimensions, temperature, flow rates, gradient slopes, buffer, pH etc.), we validated the setup using Dexcom G6 (G6) and Freestyle Libre 2 (L2) sensors with/without interferents, and using YSI 2300 Stat plus as the reference glucose device at room temperature.
resultsBoth sensors tracked the programmed glucose changes. After calibration, G6 results closely matched glucose reference readings, while L2 routinely showed ~50% to 60% lower readings, most likely because of the factory-based calibration and temperature compensation. Gradients of maltose, acetaminophen, and xylose were employed to further validate the setup. As expected, both sensors were not affected by maltose. We confirmed previous findings regarding susceptibility of G6 readings to acetaminophen and L2 readings to xylose. Signals from both sensors are influenced by temperature in a linear fashion.
conclusionsOur experimental in vitro setup and protocol may provide a useful method to dynamically test CGM sensors for interfering substances. This may help to improve the accuracy of future CGM sensor generations.