Evidence map›Paper›PMID 35548895›Full record

ArticleDiagnostic and interventional radiology (Ankara, Turkey)2022

The effect of MWA protocols upon morphology and IVIM parameters of hepatic ablation zones-a preliminary in vivo animal study with an MRI-compatible microwave ablation device.

Weitao Ye, Wanqun Yang, Chengwei Guo, Chenyu Dong, Feng Shi, Changhong Liang

Open access · greenAbstract read
In one paragraph

Article in Diagnostic and interventional radiology (Ankara, Turkey), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 46% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Weitao YeDepartment of Radiology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangdong, People's Republic of China.
Wanqun YangDepartment of Radiology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangdong, People's Republic of China.
Chengwei GuoDepartment of Radiology, 82 Group Hospital of PLA, Hebei, Province, People's Republic of China.
Chenyu DongDepartment of Radiology, the Third Affiliated Hospital of Sun Yat-Sen University, Guangdong, People's Republic of China.
Feng ShiDepartment of Interventional Radiology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangdong, People's Republic of China.
Changhong LiangDepartment of Radiology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangdong, People's Republic of China.
Guangdong Academy of Medical Sciences · CNHospital of Hebei Province · CNSun Yat-sen University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

PURPOSE We aimed to explore the effect of microwave ablation (MWA) protocols upon morphology and instant changes in intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) parameters on MWA zones in porcine livers. METHODS According to the empirical protocol for MWA in tumors less than 3 cm in our hospital, the power and application duration were assigned as five groups: A, 60 W × 5 min (n = 6); B, 80 W × 3 min (n = 7); C, 80 W × 5 min (n = 10); D, 100 W × 3 min (n = 10); E, 100 W × 5 min (n = 9). Spearman correlation between MWA protocols, morphological metrics, and instant post-ablation IVIM parameters was performed. RESULTS There was fair positive correlation between energy delivery and short axis (RSpearman = 0.426, P= .005) of the white zone. There was moderate-to-good positive correlation between wattage and short axis (RSpearman = 0.584, P < .001) of the white zone. For post-ablation IVIM parameters in the white zone, only wattage had moderate-to-good positive correlation with D value (RSpearman= 0.574, P < .001) or ADC value (RSpearman = 0.550, P < .001). No correlation between energy delivery, wattage, duration, and f value was observed (RSpearman = 0.185, P = .24; RSpearman= - 0.001, P = .99; RSpearman = 0.203, P = .20, respectively). CONCLUSION The increase in the short axis of the white zone is more likely to be affected by wattage than energy delivery. The instant post-ablation IVIM is feasible in monitoring the MWA zones since the f value in the white zones is not sensitive to changes in MWA protocols, which is promising in evaluating the instant effect of MWA.

Indexed as

MicrowavesRadiofrequency AblationAnimalsDiffusion Magnetic Resonance ImagingHumansLiverMagnetic Resonance ImagingMotionSwine

Identifiers

PMID35548895
PMCPMC12278932
OpenAlexW4225098415

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.