Evidence map›Paper›PMID 35547575›Full record

ArticleFrontiers in physiology2022

Robust Reconstruction of Electrocardiogram Using Photoplethysmography: A Subject-Based Model.

Qunfeng Tang, Zhencheng Chen, Yanke Guo, Yongbo Liang, Rabab Ward, Carlo Menon, Mohamed Elgendi

Abstract read
In one paragraph

Article in Frontiers in physiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Qunfeng TangSchool of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin, China.
Zhencheng ChenSchool of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin, China.
Yanke GuoSchool of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin, China.
Yongbo LiangSchool of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin, China.
Rabab WardDepartment of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada.
Carlo MenonBiomedical and Mobile Health Technology Laboratory, Department of Health Sciences and Technology, Zurich, Switzerland.
Mohamed ElgendiDepartment of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electrocardiography and photoplethysmography are non-invasive techniques that measure signals from the cardiovascular system. While the cycles of the two measurements are highly correlated, the correlation between the waveforms has rarely been studied. Measuring the photoplethysmogram (PPG) is much easier and more convenient than the electrocardiogram (ECG). Recent research has shown that PPG can be used to reconstruct the ECG, indicating that practitioners can gain a deep understanding of the patients' cardiovascular health using two physiological signals (PPG and ECG) while measuring only PPG. This study proposes a subject-based deep learning model that reconstructs an ECG using a PPG and is based on the bidirectional long short-term memory model. Because the ECG waveform may vary from subject to subject, this model is subject-specific. The model was tested using 100 records from the MIMIC III database. Of these records, 50 had a circulatory disease. The results show that a long ECG signal could be effectively reconstructed from PPG, which is, to our knowledge, the first attempt in this field. A length of 228 s of ECG was constructed by the model, which was trained and validated using 60 s of PPG and ECG signals. To segment the data, a different approach that segments the data into short time segments of equal length (and that do not rely on beats and beat detection) was investigated. Segmenting the PPG and ECG time series data into equal segments of 1-min width gave the optimal results. This resulted in a high Pearson's correlation coefficient between the reconstructed 228 s of ECG and referenced ECG of 0.818, while the root mean square error was only 0.083 mV, and the dynamic time warping distance was 2.12 mV per second on average.

Indexed as

cardiologydata sciencedigital healthelectrocadiogramintensive and critical carevital sign analysis

Identifiers

PMID35547575
PMCPMC9082149

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.