Evidence map›Paper›PMID 35546677›Full record

ArticleJournal of cardiothoracic surgery2022

The risk factors for the failure of hook wire localization of ground glass nodules prior to thoracoscopic surgery.

Musu Ala, Junzhong Liu, Jieli Kou, Xinhua Wang, Minfeng Sun, Changcheng Hao, Jianlin Wu

Open access · goldAbstract read
In one paragraph

Article in Journal of cardiothoracic surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Trial
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Musu AlaGraduate School, Tianjin Medical University, Tianjin, 300070, People's Republic of China.
Junzhong LiuDepartment of Radiology, Weifang People's Hospital, The First Affiliated Hospital of Weifang Medical University, Weifang, 261041, Shandong, People's Republic of China.
Jieli KouDepartment of Medical Imaging, Cangzhou People's Hospital, Cangzhou, 061001, Hebei, People's Republic of China.
Xinhua WangDepartment of Radiology, Weifang No. 2 People's Hospital, The Second Affiliated Hospital of Weifang Medical University, Weifang, 261041, Shandong, People's Republic of China.
Minfeng SunDepartment of Radiology, Weifang No. 2 People's Hospital, The Second Affiliated Hospital of Weifang Medical University, Weifang, 261041, Shandong, People's Republic of China.
Changcheng HaoThoracic Surgery Department, Weifang No. 2 People's Hospital, The Second Affiliated Hospital of Weifang Medical University, Weifang, 261041, Shandong, People's Republic of China.
Jianlin WuGraduate School, Tianjin Medical University, Tianjin, 300070, People's Republic of China. cjr.wujianlin@vip.163.com.
Weifang Medical University · CNAffiliated Zhongshan Hospital of Dalian University · CNPeople's Hospital of Cangzhou · CNTianjin Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo retrospectively analyse the potential influencing factors of CT-guided hook wire localization failure prior to thoracoscopic resection surgery of ground glass nodules (GGNs), and determine the main risk elements for localization failure.

methodsIn all, 372 patients were included in this study, with 21 patients showing localization failure. The related parameters of patients, GGNs, and localization were analysed through univariate and multiple logistic regression analysis to determine the risk factors of localization failure.

resultsUnivariate logistic regression analysis indicated that trans-fissure (odds ratio [OR] 4.896, 95% confidence interval [CI] 1.489-13.939); trans-emphysema (OR 3.538, 95% CI 1.343-8.827); localization time (OR 0.956, 95% CI 0.898-1.019); multi-nodule localization (OR 2.597, 95% CI 1.050-6.361); and pneumothorax (OR 10.326, 95% CI 3.414-44.684) were risk factors for localization failure, and the p-values of these factors were < 0.05. However, according to the results of multivariate analysis, pneumothorax (OR 5.998, 95% CI 1.680-28.342) was an exclusive risk factor for the failure of preoperative localization of GGNs.

conclusionCT-guided hook wire localization of GGNs prior to thoracoscopic surgery is often known to fail; however, the incidence is low. Pneumothorax is an independent risk factor for failure in the localization process.

Indexed as

Lung NeoplasmsPneumothoraxSolitary Pulmonary NoduleHumansRetrospective StudiesRisk FactorsThoracic Surgery, Video-AssistedGround glass noduleLocalizationPneumothoraxThoracoscopic surgery

Identifiers

PMID35546677
PMCPMC9092699
OpenAlexW4280529458

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked