ArticleScientific reports2022
The repeatability and agreement of biometric measurements by dual Scheimpflug device with integrated optical biometer.
Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07325162 (Development of a Next-Generation Optical Biometer for Eyes With Cataract), which is not on this map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Development of a Next-Generation Optical Biometer for Eyes With Cataract
Who cites it
3 citing papers in PubMed, 2 citations in OpenAlex.
- Repeatability of keratometry depending on tear film osmolarity.Acta ophthalmologica · 2026Article
- Agreement between a swept-source optical coherence tomography and dual Scheimpflug Placido analyser in healthy, keratoconus suspect and keratoconus eyes.BMC ophthalmology · 2026Article
- Correlations among Corneal Biomechanical Parameters, Stiffness, and Thickness Measured Using Corvis ST and Pentacam in Patients with Ocular Hypertension.Journal of ophthalmology · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
To determine the repeatability of biometric measurements by dual Scheimpflug Devices with Integrated Optical Biometers and its agreement with partial coherence interferometry according to the axial length (AL), and the presence of cataracts. The present population-based cross-sectional study was conducted on the geriatric population in Tehran. For participants, imaging was performed by dual Scheimpflug Devices with Integrated Optical Biometers (Galilei G6) and partial coherence interferometry (IOL Master 500). All measurements were performed by one person. In both normal and cataractous eyes, the ICC values were above 0.99 for three measurements of AL, intraocular lens (IOL) power target, anterior chamber depth (ACD), central corneal thickness (CCT), flat and steep keratometry readings, and mean total corneal power (MTCP). The repeatability coefficient for the AL measurements was 0.003 and 0.002 in eyes with and without cataracts, respectively. The mean difference of AL between IOL Master 500 and Galilei G6 in normal and cataractous eyes was 0.015 and -0.003 mm, respectively. The 95% limits of agreement (LoA) of AL between these two devices were -0.09 to 0.12 mm in normal and -0.09 to 0.08 mm in cataractous eyes. The 95% LoA of ACD between the two devices was -0.13 to 0.36 mm and -0.10 to 0.31 mm in eyes without and with cataracts, respectively. The 95% LoA of steep K between the two devices was -0.63 to 0.32 and -1.04 to 0.89 diopter in normal and cataractous eyes, respectively. The results of the present study indicate the high repeatability of Galilei G6 in ocular biometric measurements. Galilei biometric measurements, had a very high agreement with the IOL Master 500.