Evidence map›Paper›PMID 35546598›Full record

ArticleScientific reports2022

Phase-matched high-order harmonic generation in pre-ionized noble gases.

O Finke, J Vábek, M Nevrkla, N Bobrova, O Hort, L Jurkovičová, M Albrecht, A Jančárek, F Catoire, S Skupin and 1 more

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
1.1field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 8 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 6 institutions in 2 countries.

O FinkeELI Beamlines Centre, FZU-Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 21, Prague, Czechia.
J VábekELI Beamlines Centre, FZU-Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 21, Prague, Czechia.
M NevrklaELI Beamlines Centre, FZU-Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 21, Prague, Czechia.
N BobrovaCzech Technical University in Prague, FNSPE, Břehová 7, 115 19, Prague 1, Czechia.
O HortELI Beamlines Centre, FZU-Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 21, Prague, Czechia.
L JurkovičováELI Beamlines Centre, FZU-Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 21, Prague, Czechia.
M AlbrechtELI Beamlines Centre, FZU-Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 21, Prague, Czechia.
A JančárekELI Beamlines Centre, FZU-Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 21, Prague, Czechia.
F CatoireCentre Des Lasers Intenses et Applications, Université de Bordeaux-CNRS-CEA, 33405, Talence Cedex, France.
S SkupinInstitut Lumière Matière, UMR 5306 Université Lyon 1-CNRS, Université de Lyon, 69622, Villeurbanne, France.
J NejdlELI Beamlines Centre, FZU-Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 21, Prague, Czechia. nejdl@fzu.cz.
Czech Academy of Sciences · CZExtreme Light Infrastructure Beamlines · CZCzech Technical University in Prague · CZCentre National de la Recherche Scientifique · FRCzech Academy of Sciences, Institute of Physics · CZUniversité de Bordeaux · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

One of the main difficulties of efficiently generating high-order harmonics in long neutral-gas targets is to reach the phase-matching conditions. The issue is that the medium cannot be sufficiently ionized by the driving laser due to plasma defocusing. We propose a method to improve the phase-matching by pre-ionizing the gas using a weak capillary discharge. We have demonstrated this mechanism, for the first time, in absorption-limited XUV generation by an 800 nm femtosecond laser in argon and krypton. The ability to control phase-mismatch is confirmed by an analytical model and numerical simulations of the entire generation process. Our method allows to increase the efficiency of the harmonic generation significantly, paving the way towards photon-hungry applications of these compact short-wavelength sources.

Identifiers

PMID35546598
PMCPMC9095879
OpenAlexW4221158483

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.