Evidence map›Paper›PMID 35544557›Full record

ArticleScience advances2022

Fully implantable wireless batteryless vascular electronics with printed soft sensors for multiplex sensing of hemodynamics.

Robert Herbert, Hyo-Ryoung Lim, Bruno Rigo, Woon-Hong Yeo

Open access · goldAbstract read
In one paragraph

Article in Science advances, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 56 papers.

0numbers the graph read from it
0cells of the map it votes in
56citing papers in PubMed
9.4field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

56 citing papers in PubMed, 133 citations in OpenAlex.

  1. Review
  2. Soft robotic devices for cardiovascular medicine.Nature reviews. Cardiology · 2026
    Review
  3. Review
  4. Review
  5. Review
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Review
  13. Article
  14. Article
  15. Review
  16. Article
  17. Review
  18. Review
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Robert HerbertGeorge W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.ORCID 0000-0001-9885-0684
Hyo-Ryoung LimMajor of Human Biocovergence, Division of Smart Healthcare, College of Information Technology and Convergence, Pukyong National University, Busan, 48513, Republic of Korea.ORCID 0000-0002-0828-2853
Bruno RigoIEN Center for Human-Centric Interfaces and Engineering at the Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA 30332, USA.ORCID 0000-0002-1068-515X
Woon-Hong YeoGeorge W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.ORCID 0000-0002-5526-3882
Georgia Institute of Technology · USPukyong National University · KR

Funding

Smart Electronic Stent for Surveillance of Coronary Artery RestenosisR03EB028928 · NIBIB · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI CHUN, YOUNG JAE · 2020 to 2020
$157k
NIBIB NIH HHS R03 EB028928
6 · The paper itself

Abstract

The continuous monitoring of hemodynamics attainable with wireless implantable devices would improve the treatment of vascular diseases. However, demanding requirements of size, wireless operation, and compatibility with endovascular procedures have limited the development of vascular electronics. Here, we report an implantable, wireless vascular electronic system, consisting of a multimaterial inductive stent and printed soft sensors capable of real-time monitoring of arterial pressure, pulse rate, and flow without batteries or circuits. Developments in stent design achieve an enhanced wireless platform while matching conventional stent mechanics. The fully printed pressure sensors demonstrate fast response times, high durability, and sensing at small bending radii. The device is monitored via inductive coupling at communication distances notably larger than prior vascular sensors. The wireless electronic system is validated in artery models, while minimally invasive catheter implantation is demonstrated in an in vivo rabbit study. Overall, the vascular system offers an adaptable framework for comprehensive monitoring of hemodynamics.

Identifiers

PMID35544557
PMCPMC9094660
OpenAlexW4280514966

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.