Evidence map›Paper›PMID 35542691›Full record

ArticleResuscitation plus2022

Automated aortic endovascular balloon volume titration prevents re-arrest immediately after return of spontaneous circulation in a swine model of nontraumatic cardiac arrest.

Craig D Nowadly, M Austin Johnson, Scott T Youngquist, Timothy K Williams, Lucas P Neff, Guillaume L Hoareau

Open access · goldAbstract read
In one paragraph

Article in Resuscitation plus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.8field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Craig D NowadlyDepartment of Emergency Medicine, Brooke Army Medical Center, San Antonio, TX, United States.
M Austin JohnsonDepartment of Emergency Medicine, University of Utah, School of Medicine, Salt Lake City, UT, United States.
Scott T YoungquistDepartment of Emergency Medicine, University of Utah, School of Medicine, Salt Lake City, UT, United States.
Timothy K WilliamsDepartment of Vascular and Endovascular Surgery, Atrium Health Wake Forest Baptist, Winston-Salem, NC, United States.
Lucas P NeffDepartment of General Surgery, Atrium Health Wake Forest Baptist, Winston-Salem, NC, United States.
Guillaume L HoareauDepartment of Emergency Medicine, University of Utah, School of Medicine, Salt Lake City, UT, United States.
Atrium Health Wake Forest Baptist · USUniversity of Utah · USNew York City Fire Department · USSan Antonio Military Medical Center · US

Funding

Utah Center for Clinical and Translational ScienceUL1TR002538 · NCATS · UNIVERSITY OF UTAH · PI HESS, RACHEL, MAJERSIK, JENNIFER JUHL · 2018 to 2022
$26.0M
Vascular Health and Risk Factors in Children with Down SyndromeKL2TR002539 · NCATS · UNIVERSITY OF UTAH · PI MURTAUGH, MAUREEN A, NYGAARD, INGRID E · 2018 to 2022
$4.3M
NCATS NIH HHS KL2 TR002539NCATS NIH HHS UL1 TR002538
6 · The paper itself

Abstract

Objectives: Endovascular aortic occlusion as an adjunct to cardiopulmonary resuscitation (CPR) for non-traumatic cardiac arrest is gaining interest. In a recent clinical trial, return of spontaneous circulation (ROSC) was achieved despite prolonged no-flow times. However, 66% of patients re-arrested upon balloon deflation. We aimed to determine if automated titration of endovascular balloon volume following ROSC can augment diastolic blood pressure (DBP) to prevent re-arrest. Methods: Twenty swine were anesthetized and placed into ventricular fibrillation (VF). Following 7 minutes of no-flow VF and 5 minutes of mechanical CPR, animals were subjected to complete aortic occlusion to adjunct CPR. Upon ROSC, the balloon was either deflated steadily over 5 minutes (control) or underwent automated, dynamic adjustments to maintain a DBP of 60 mmHg (Endovascular Variable Aortic Control, EVAC). Results: ROSC was obtained in ten animals (5 EVAC, 5 REBOA). Sixty percent (3/5) of control animals rearrested while none of the EVAC animals rearrested ( Conclusion: In our swine model of cardiac arrest, automated aortic endovascular balloon titration improved DBP and prevented re-arrest in the first 20 minutes after ROSC.

Indexed as

ArrhythmiasCardiopulmonary resuscitationEndovascular proceduresIntra-aortic balloonResuscitationResuscitative endovascular balloon occlusion of the aorta

Identifiers

PMID35542691
PMCPMC9079240
OpenAlexW4225262804

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.