ArticleERJ open research2022
Plethysmography-derived gas trapping lacks utility in predicting response to bronchial thermoplasty.
Article in ERJ open research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
There is a paucity of literature on measurable baseline parameters predicting response and guiding selection for bronchial thermoplasty. This study examines whether baseline gas trapping, as assessed by plethysmography, is associated with a response to bronchial thermoplasty at 12 months. 43 consecutive patients with severe asthma (mean±sd age 57.6±13.3 years) were evaluated at baseline and 12 months post bronchial thermoplasty. Data collected at both time points included spirometry, body plethysmography and four clinical outcome measures, namely Asthma Control Questionnaire (ACQ) score, annual exacerbation frequency, maintenance oral corticosteroid requirement and short-acting β-agonist use. At baseline, participants had severe airflow obstruction (forced expiratory volume in 1 s 49.1±15.8%) with marked gas trapping (residual volume (RV) 150.3±40.8%, RV/total lung capacity (TLC) 51.3±10.5%), poor symptom control (ACQ 3.3±1.0) and frequent exacerbations (median 4, interquartile range 8). 12 months after bronchial thermoplasty, significant improvements were observed in all four clinical outcome measures. However, baseline RV and RV/TLC were not significantly associated with changes in ACQ nor any other clinical outcome measure, and changes in RV and RV/TLC did not significantly correlate with a change in any clinical outcome measure. Plethysmography-derived gas trapping does not demonstrate utility in predicting response and guiding selection for bronchial thermoplasty. An improvement in gas trapping was not associated with positive clinical outcomes, suggesting that this may not be the dominant mode of action of bronchial thermoplasty in generating clinical improvement.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.