Consistency Analysis of 3 Detection Systems for Measuring Serum C-Reactive Protein.

Xueyan Chen, Chuanyihong Huang, Weichuan Zhong, Suwen Qi, Ting Huang, Zihua Yang

Open access · greenAbstract read
In one paragraph

Article in Medical science monitor : international medical journal of experimental and clinical research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 54% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Xueyan ChenDepartment of Clinical Laboratory, The People's Hospital of Longhua Shenzhen, Shenzhen, Guangdong, China (mainland).
Chuanyihong HuangDepartment of Clinical Laboratory, The People's Hospital of Longhua Shenzhen, Shenzhen, Guangdong, China (mainland).
Weichuan ZhongDepartment of Clinical Laboratory, The People's Hospital of Longhua Shenzhen, Shenzhen, Guangdong, China (mainland).
Suwen QiDepartment of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen, Guangdong, China (mainland).
Ting HuangShenzhen Jingfang Industrial Development Co., Ltd., Shenzhen, Guangdong, China (mainland).
Zihua YangDepartment of Clinical Laboratory, The Second Clinical Medical College of Jinan University, First Affiliated Hospital of Southern University of Science and Technology, Shenzhen People's Hospital, Shenzhen, Guangdong, China (mainland).
ShenZhen People’s Hospital · CNJinan University · CNShenzhen University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND C-reactive protein (CRP) is an important clinical indicator. There are many methods and instruments for CRP measurement, and therefore the consistency of CRP values measured between instruments needs to be evaluated. This study aimed to compare the consistency of 3 serum CRP detection systems using turbidimetry. MATERIAL AND METHODS The consistency of CRP measured by 3 instruments, the Mindray BC-5390, Mindray BC-6800, and Johnson Vitros5600, was evaluated, and the consistency of blood routine measurement between the BC-5390 and BC-6800 was also evaluated. Pearson correlation analysis was used to evaluate the correlation of different instrument's test results (R, correlation coefficient). The consistency of instruments was assessed by Passing-Bablok analysis and weighted Deming analysis. RESULTS CRP data and route blood test data from 847 patients were used for analysis. The results showed that there were differences in the CRP values measured by the Mindray BC5390, Mindray BC6800, and Johnson Vitros5600 (χ²=78.573, P<0.001). The CRP measurement results of the BC5390 analyzer were consistent with those of the BC6800 analyzer (R=0.994, P<0.001) and Vitros5600 analyzer (R=0.983, P<0.001). However, there was a constant deviation in the CRP values measured by the BC-6800 and Vitros5600 analyzer (R=0.994, P<0.001). In the measurement of routine blood laboratory tests, the BC5390 analyzer and BC6800 analyzer were found to be interchangeable. CONCLUSIONS This study analyzed the consistency of CRP detection by 3 instruments, the Mindray BC-5390, Mindray BC-6800, and Johnson Vitros5600, and may provide a reference for the selection of CRP detection instruments.

Indexed as

C-Reactive ProteinHematologyBlood Cell CountHematologic TestsHumansReproducibility of ResultsC-Reactive Protein

Identifiers

PMID35538647
PMCPMC9109607
OpenAlexW4220904651

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.