Evidence map›Paper›PMID 35535218›Full record

ArticleJournal of medical and biological engineering2022

Photoplethysmography-Based Respiratory Rate Estimation Algorithm for Health Monitoring Applications.

Talha Iqbal, Adnan Elahi, Sandra Ganly, William Wijns, Atif Shahzad

Abstract read
In one paragraph

Article in Journal of medical and biological engineering, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Exhaled Breath Analysis: From Laboratory Test to Wearable Sensing.IEEE reviews in biomedical engineering · 2025
    Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Talha IqbalSmart Sensor Lab, Lambe Institute of Translational Research, College of Medicine, Nursing Health Sciences, National University of Ireland, Galway, H91 TK33 Ireland.ORCID 0000-0001-9505-2732
Adnan ElahiDepartment of Electrical Engineering, National University of Ireland, Galway, H91 TK33 Ireland.
Sandra GanlySmart Sensor Lab, Lambe Institute of Translational Research, College of Medicine, Nursing Health Sciences, National University of Ireland, Galway, H91 TK33 Ireland.
William WijnsSmart Sensor Lab, Lambe Institute of Translational Research, College of Medicine, Nursing Health Sciences, National University of Ireland, Galway, H91 TK33 Ireland.
Atif ShahzadSmart Sensor Lab, Lambe Institute of Translational Research, College of Medicine, Nursing Health Sciences, National University of Ireland, Galway, H91 TK33 Ireland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Respiratory rate can provide auxiliary information on the physiological changes within the human body, such as physical and emotional stress. In a clinical setup, the abnormal respiratory rate can be indicative of the deterioration of the patient's condition. Most of the existing algorithms for the estimation of respiratory rate using photoplethysmography (PPG) are sensitive to external noise and may require the selection of certain algorithm-specific parameters, through the trial-and-error method. Methods: This paper proposes a new algorithm to estimate the respiratory rate using a photoplethysmography sensor signal for health monitoring. The algorithm is resistant to signal loss and can handle low-quality signals from the sensor. It combines selective windowing, preprocessing and signal conditioning, modified Welch filtering and postprocessing to achieve high accuracy and robustness to noise. Results: The Mean Absolute Error and the Root Mean Square Error of the proposed algorithm, with the optimal signal window size, are determined to be 2.05 breaths count per minute and 2.47 breaths count per minute, respectively, when tested on a publicly available dataset. These results present a significant improvement in accuracy over previously reported methods. The proposed algorithm achieved comparable results to the existing algorithms in the literature on the BIDMC dataset (containing data of 53 subjects, each recorded for 8 min) for other signal window sizes. Conclusion: The results endorse that integration of the proposed algorithm to a commercially available pulse oximetry device would expand its functionality from the measurement of oxygen saturation level and heart rate to the continuous measurement of the respiratory rate with good efficiency at home and in a clinical setting. Supplementary Information: The online version contains supplementary material available at 10.1007/s40846-022-00700-z.

Indexed as

Adaptive estimationAlgorithmsHealth monitoringPhotoplethysmographyRespiratory rateWearable sensors

Identifiers

PMID35535218
PMCPMC9056464

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.