Evidence map›Paper›PMID 35534732›Full record

ArticleSurgical endoscopy2022

Safe oesophageal stent deployment using a checklist system instead of fluoroscopy.

Muhammad S Khanzada, Abdelmonim E A Salih, Michael R Boland, Thomas N Walsh

Abstract read
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 49% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Muhammad S KhanzadaDepartment of Surgery, Connolly Hospital Blanchardstown, Dublin 15, Ireland. salman_khan5656@yahoo.com.
Abdelmonim E A SalihDepartment of Surgery, Connolly Hospital Blanchardstown, Dublin 15, Ireland.
Michael R BolandDepartment of Surgery, Connolly Hospital Blanchardstown, Dublin 15, Ireland.
Thomas N WalshDepartment of Surgery, Connolly Hospital Blanchardstown, Dublin 15, Ireland.
Connolly Hospital Blanchardstown · IERoyal College of Surgeons in Ireland · IE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundStenting is the management of choice for many benign and malignant oesophageal conditions and in the interest of safety stent insertion has traditionally been performed under fluoroscopic guidance. But this incurs additional expense, time, radiation risk and for the foreseeable future, an increased risk of Covid infection to patients and healthcare personnel. We describe a protocol that obviates the need for fluoroscopic guidance, relying instead on a systematic checklist to ensure safe positioning of the guidewire and the accurate positioning of the stent. The aim of this retrospective study was to review our experience of stent insertion employing a checklist system and compare our outcomes with outcomes using fluoroscopy in the literature.

methodsWe performed a retrospective review of a prospectively collected dataset of all patients undergoing oesophageal stent insertion between December 2007 and October 2019. The primary end points were patient safety parameters and complications of stent insertion.

resultsTotal of 163 stents were deployed of which 93 (57%) were in males and the median age was 67.9 years (25-92 years). Partially covered self-expanding metallic stents (SEMS) were used in 80% of procedures (130/163). One hundred nineteen stents (73%) were for malignant strictures and 127 (78%) were deployed for strictures in the lower third of the oesophagus. There was no stent misplacement, injury, perforation or death associated with the procedure. Vomiting was the main post-operative complication (14%). Severe odynophagia necessitated stent removal in 3 patients. Stent migration occurred in 17 (10%) procedures with a mean time to stent migration of 6.4 weeks (range 1-20 weeks).

conclusionsOesophageal stent placement without fluoroscopy is safe provided that a strict checklist is adhered to. The outcomes are comparable to the results of fluoroscopic stent placement in the literature, with considerable saving in time, cost, personnel, and risks of radiation and Covid exposure.

Indexed as

COVID-19Esophageal NeoplasmsAgedChecklistConstriction, PathologicEsophagusFluoroscopyHumansMalePalliative CareRetrospective StudiesStentsTreatment OutcomeChecklistFluoroscopic guidedOesophageal carcinomaOesophageal stentsStentingStrictures

Identifiers

PMID35534732
OpenAlexW4229442894

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.