ArticleGeriatric orthopaedic surgery & rehabilitation2022
Use of the Locking Attachment Plate for Internal Fixation of Periprosthetic Femur Fractures.
Article in Geriatric orthopaedic surgery & rehabilitation, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 8 citations in OpenAlex.
- Does an additional attachment plate improve fixation in Vancouver type B1 and C periprosthetic femoral fractures? A retrospective comparative study.BMC musculoskeletal disorders · 2025Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: The locking attachment plate (LAP) can be added to a locking compression plate (LCP) to allow the fixation of locking screws bicortically around a femoral implant. We aimed to examine surgical and fracture characteristics associated with healing for periprosthetic femur fractures (PPFFx) treated with constructs employing LAP fixation. We hypothesize that the addition of an LAP provides stable peri-implant fixation. Materials &Methods: We retrospectively reviewed a consecutive series of 28 PPFFx surgically treated with LCP-LAP constructs by 4 surgeons from 2015-2020. Fractures were classified and grouped using the Vancouver Classification System and included 12 B1, 2 B2, 11 C fractures, and 3 fractures around other stemmed implants. Primary outcome measures included hardware failure such as screw pullout, broken screws, and plate fracture. Clinical complications including infection, non-union, malunion, and reoperation were recorded. Results: No LAP failures, screw pullout, or broken screws were observed. Two fractured plates (7.1%) occurred in patients with Vancouver C fracture types. Overall complication rate was 17.9% and included 3 non-unions, 1 deep infection, and 1 implant loosening with painful hardware, each requiring reoperation. Differences were observed between unions and nonunions for total number of screws (12.4 vs 14.7, Conclusion: The LAP provides adequate fixation and low failure rates where fixation is required around a well-fixed stem. When failures occur, it is from plate breakage and not due to failure of fixation at the area of plate-stem overlap.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.