ArticleHeliyon2022
An archetypal model of a breathable air-circuit in an electro-pneumatic ventilator device.
Article in Heliyon, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 5 citations in OpenAlex.
- Study protocol: post-harvest losses of fruits and vegetables and their relationship with the nutritional status of women and children.Frontiers in public health · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Mechanical ventilator is a machine that is mechanically designed to deliver breathable air in and out of the lungs to provide a breathing mechanism for a patient who is physically unable to breathe, it is an indispensable life-support device in critical care medicine and medical emergencies such as scenarios during the COVID-19 pandemic. This research presents a model design of the pneumatic circuit that is electronically controlled, by using computer-aided pneumatic rig over selected 5/3, 5/2, 3/2 solenoid gating valves, the performance of these valves must be investigated to ascertain the most appropriate valve to be used for the electro-pneumatic mechanical ventilator. An elaborate parametric investigation reported for volume-controlled ventilators illustrate the influences of key parameters on the dynamics of the ventilated respiratory system. This study presents the linearity of tidal volume, peak pressure and lung compliance for the parameters considered. However, the maximum pressure of the ventilation device increases slowly when the tidal volumes exceed 600 ml. In addition, influence of evacuation time of the ventilator predicted over high throughput in time regimes of 1 s; 1.2 s; 1.4 s; 1.6 s, and 1.8 s showed that the pressure platform in the pipe might not appear if the exhaust time of the ventilator is less than 1.6 s. The 5/2 solenoid valve was considered the best with consistent flowrate. The archetypal model of the pneumatic circuit developed in this research could find vital application in the design of patient-interfacing devices particularly in ventilators and neonatal incubator.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.