Evidence map›Paper›PMID 35529341›Full record

ArticleBiomedical engineering letters2022

Deep thrombosis characterization using photoacoustic imaging with intravascular light delivery.

Yuqi Tang, Huaiyu Wu, Paul Klippel, Bohua Zhang, Hsiao-Ying Shadow Huang, Yun Jing, Xiaoning Jiang, Junjie Yao

Open access · greenAbstract read
In one paragraph

Article in Biomedical engineering letters, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.1field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Photoacoustic imaging for microcirculation.Microcirculation (New York, N.Y. : 1994) · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Yuqi Tang *Department of Biomedical Engineering, Duke University, Durham, NC USA.ORCID 0000-0003-0419-5004
Huaiyu Wu *Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC USA.
Paul KlippelGraduate Program in Acoustics and Department of Biomedical Engineering, Pennsylvania State University, University Park, PA USA.
Bohua ZhangDepartment of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC USA.
Hsiao-Ying Shadow HuangDepartment of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC USA.
Yun JingGraduate Program in Acoustics and Department of Biomedical Engineering, Pennsylvania State University, University Park, PA USA.
Xiaoning JiangDepartment of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC USA.
Junjie YaoDepartment of Biomedical Engineering, Duke University, Durham, NC USA.
North Carolina State University · USDuke University · USPennsylvania State University · US

Funding

Integrated Dual-frequency Ultrasound Catheter for Accelerated Sonothrombolysis (iDUCAS)R01HL141967 · NHLBI · NORTH CAROLINA STATE UNIVERSITY RALEIGH · PI Xiaoning Jiang, Zhen Xu · 2018 to 2026
$4.1M
High-resolution High-speed Photoacoustic and Ultrasound Imaging of SmallVessel Functions in Ischemic StrokeR01NS111039 · NINDS · DUKE UNIVERSITY · PI YAO, JUNJIE · 2019 to 2023
$2.7M
Head-mounted Photoacoustic Imaging of Deep-brain Neural Activities in Freely Behaving AnimalsRF1NS115581 · NINDS · DUKE UNIVERSITY · PI VERKHUSHA, VLADISLAV, YAO, JUNJIE · 2020 to 2020
$2.0M
High-Throughput Volumetric Photoacoustic Imaging of Living Vascularized OrganoidsR01EB028143 · NIBIB · DUKE UNIVERSITY · PI YAO, JUNJIE · 2019 to 2022
$2.0M
Toward an accuracy-efficiency balanced model for modeling high intensity focused ultrasoundR01EB025205 · NIBIB · PENNSYLVANIA STATE UNIVERSITY, THE · PI JING, YUN · 2018 to 2020
$955k
Transcranial Photoacoustic Imaging Using a Virtual ArrayR21EB027981 · NIBIB · PENNSYLVANIA STATE UNIVERSITY, THE · PI JING, YUN · 2020 to 2020
$455k
Photoacoustic-imaging-guided intravascular sonothrombolysisR21EB027304 · NIBIB · NORTH CAROLINA STATE UNIVERSITY RALEIGH · PI JIANG, XIAONING, YAO, JUNJIE · 2019 to 2020
$411k
NHLBI NIH HHS R01 HL141967NIBIB NIH HHS R01 EB025205NIBIB NIH HHS R01 EB028143NIBIB NIH HHS R21 EB027304NIBIB NIH HHS R21 EB027981NINDS NIH HHS R01 NS111039NINDS NIH HHS RF1 NS115581
6 · The paper itself

Abstract

Venous thromboembolism (VTE) is a condition in which blood clots form within the deep veins of the leg or pelvis to cause deep vein thrombosis. The optimal treatment of VTE is determined by thrombus properties such as the age, size, and chemical composition of the blood clots. The thrombus properties can be readily evaluated by using photoacoustic computed tomography (PACT), a hybrid imaging modality that combines the rich contrast of optical imaging and deep penetration of ultrasound imaging. With inherent sensitivity to endogenous chromophores such as hemoglobin, multispectral PACT can provide composition information and oxygenation level in the clots. However, conventional PACT of clots relies on external light illumination, which provides limited penetration depth due to strong optical scattering of intervening tissue. In our study, this depth limitation is overcome by using intravascular light delivery with a thin optical fiber. To demonstrate in vitro blood clot characterization, clots with different acuteness and oxygenation levels were placed underneath ten-centimeter-thick chicken breast tissue and imaged using multiple wavelengths. Acoustic frequency analysis was performed on the received PA channel signals, and oxygenation level was estimated using multispectral linear spectral unmixing. The results show that, with intravascular light delivery, clot oxygenation level can be accurately measured, and the clot age can thus be estimated. In addition, we found that retracted and unretracted clots had different acoustic frequency spectrum. While unretracted clots had stronger high frequency components, retracted clots had much higher low frequency components due to densely packed red blood cells. The PACT characterization of the clots was consistent with the histology results and mechanical tests.

Indexed as

Blood oxygenationInternal light illuminationPhotoacoustic frequencyPhotoacoustic tomographyRetracted blood clotThrombosisUnretracted blood clot

Identifiers

PMID35529341
PMCPMC9046522
OpenAlexW4226368050

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.