Evidence map›Paper›PMID 35527810›Full record

ArticleIEEE sensors journal2021

Self-Powered Load Sensing Circuitry for Total Knee Replacement.

Manav Jain, Nabid Aunjum Hossain, Shahrzad Towfighian, Ryan Willing, Milutin Stanaćević, Emre Salman

Abstract read
In one paragraph

Article in IEEE sensors journal, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Porous Triboelectric Nanogenerator for Load Sensing of Total Knee Replacement.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. State-of-the-Art Power Transfer Methods in Triboelectric Energy Harvesters.IEEE circuits and systems magazine (New York, N.Y. : 2001)
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Manav JainStony Brook University (SUNY), Stony Brook, NY, USA.
Nabid Aunjum HossainBinghamton University (SUNY), Binghamton, NY, USA.
Shahrzad TowfighianBinghamton University (SUNY), Binghamton, NY, USA.
Ryan WillingUniversity of Western Ontario, London, Canada.
Milutin StanaćevićStony Brook University (SUNY), Stony Brook, NY, USA.
Emre SalmanStony Brook University (SUNY), Stony Brook, NY, USA.

Funding

An implantable self-powered load sensor for total knee replacement health monitoringR21AR068572 · NIAMS · STATE UNIVERSITY OF NY,BINGHAMTON · PI SALMAN, EMRE, TOWFIGHIAN, SHAHRZAD · 2017 to 2018
$349k
NIAMS NIH HHS R21 AR068572
6 · The paper itself

Abstract

There has been a significant increase in the number of total knee replacement (TKR) surgeries over the past few years, particularly among active young and elderly people suffering from knee pain. Continuous and optimal monitoring of the load on the knee is highly desirable for designing more reliable knee implants. This paper focuses on designing a smart knee implant consisting of a triboelectric energy harvester and a frontend electronic system to process the harvested signal for monitoring the knee load. The harvester produces an AC signal with peak voltages ranging from 10 V to 150 V at different values of knee cyclic loads. This paper demonstrates the measurement results of a PCB prototype of the frontend electronic system fabricated to verify the functionality and feasibility of the proposed approach for a small range of cycling load. The frontend electronic system consists of a voltage processing unit to attenuate high peak voltages, a rectifier and a regulator to convert the input AC signal into a stabilized DC signal. The DC voltage signal provides biasing for the delta-sigma analog-to-digital converter (ADC). Thus, the output of the triboelectric harvester acts as both the power signal that is rectified/regulated and data signal that is digitized. The power consumption of the proposed PCB design is approximately 5.35

Indexed as

frontend electronicsharvesterPCB prototypesmart knee implanttotal knee replacement (TKR)triboelectricvoltage processing

Identifiers

PMID35527810
PMCPMC9075162

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.