Evidence map›Paper›PMID 35524829›Full record

ArticleEuropean journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology2022

Validation study of an automated chemiluminiscence assay to detect HIV antibodies in oral fluid specimens.

Victoria González, Nalia López, Joan Grifols, Laia Egea, Belén Rivaya, Jun Hao Wang Wang, Jordi Casabona, Pere Joan Cardona

Open access · bronzeAbstract read
In one paragraph

Article in European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 55% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 6 institutions in 1 country.

Victoria GonzálezCentre for Epidemiological Studies On Sexually Transmitted Diseases and HIV/AIDS of Catalonia (CEEISCAT), Health Department, Generalitat de Catalunya, Barcelona, Spain. vgsoler@iconcologia.net.
Nalia LópezLluita Contra La SIDA Foundation, Badalona, Spain.
Joan GrifolsBanc de Sang I Teixits, Hospital Universitari Germans Trias I Pujol, Badalona, Spain.
Laia EgeaMicrobiology Department, Laboratori Clínic Metropolitana Nord, University Hospital "Germans Trias I Pujol", Badalona, Spain.
Belén RivayaMicrobiology Department, Laboratori Clínic Metropolitana Nord, University Hospital "Germans Trias I Pujol", Badalona, Spain.
Jun Hao Wang WangMicrobiology Department, Laboratori Clínic Metropolitana Nord, University Hospital "Germans Trias I Pujol", Badalona, Spain.
Jordi CasabonaCentre for Epidemiological Studies On Sexually Transmitted Diseases and HIV/AIDS of Catalonia (CEEISCAT), Health Department, Generalitat de Catalunya, Barcelona, Spain.
Pere Joan CardonaMicrobiology Department, Laboratori Clínic Metropolitana Nord, University Hospital "Germans Trias I Pujol", Badalona, Spain.
Hospital Universitari Germans Trias i Pujol · ESUniversitat Autònoma de Barcelona · ESBanc de Sang i Teixits · ESCentro de Investigación Biomédica en Red de Epidemiología y Salud Pública · ESGovernment of Catalonia · ESRed de Investigación en Sida · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Oral fluid specimens (OF) have been widely used to know the HIV prevalence in several key populations. Here, we aim to validate in OF specimens an existing HIV chemiluminiscence assay for serum specimens. Paired OF and serum specimens were collected from 83 known HIV-positives and 83 known HIV-negatives in order to validate the performance characteristics of the automated chemiluminiscence Liaison XL Murex HIV Ag/Ab assay (Diasorin Inc, Iberia) for HIV antibody detection in OF specimens. Among the previously known HIV-seropositive group, HIV antibodies were detected in 69 out of 83 OF specimens. All serum and OF specimens collected from 83 HIV seronegative individuals were negative. The sensitivity and specificity of this assay were 83.13% and 100% respectively in OF. The PPV and NPV values were 100% and 85.57% respectively. The correlation obtained between both specimens was (K: 0.83, [95% CI: 0.748-0.915]) according to the kappa index. The ROC curve analysing the optimal cut-off of the Liaison XL Murex HIV Ag/Ab to detect positive OF specimens revealed that a cut-off of 0.497 showed sensitivity and specificity values of 98.8% and 97.59% respectively. Taking into account this cut-off, the overall sensitivity and NPV of the Liaison XL Murex HIV Ag/Ab assay could rise from 83.1 to 98.8% and from 85.5 to 97.7%, respectively. Our results suggest that the Liaison XL HIV Ag/Ab assay is suitable for the detection of HIV antibodies in OF specimens.

Indexed as

HIV-1HIV InfectionsHIV AntibodiesHumansSensitivity and SpecificityHIV AntibodiesAntibodiesAutomated chemiluminiscence assayHIVOral fluid

Identifiers

PMID35524829
PMCPMC9078087
OpenAlexW4229022312

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.