Evidence map›Paper›PMID 35524194›Full record

Observational studyBMC pediatrics2022

Hemodynamic parameters after Delayed Cord Clamping (DCC) in term neonates: a prospective observational study.

Bhvya Gupta, Rameshwor Yengkhom, Nishant Banait, Chinmay Chetan, Prince Pareek, Pradeep Suryawanshi

Open access · goldAbstract readObservational Study
In one paragraph

Observational study in BMC pediatrics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 5 institutions in 1 country.

Bhvya GuptaSparsh Superspeciality Hospital, Ambala city, Haryana, India.
Rameshwor YengkhomJawaharlal Nehru Institute of Medical Sciences, Imphal, Manipur, India.
Nishant BanaitAll India Institute of Medical Sciences, Nagpur, Maharashtra, India.
Chinmay ChetanHimalayan Institute of Medical Sciences, Dehradun, Uttarakhand, India.
Prince PareekDepartment of Neonatology, Bharati Vidyapeeth University Medical College, Dhankawadi Pune, Maharashtra, 411043, India.
Pradeep SuryawanshiDepartment of Neonatology, Bharati Vidyapeeth University Medical College, Dhankawadi Pune, Maharashtra, 411043, India. drpradeepsuryawanshi@gmail.com.
Bharati Vidyapeeth Deemed University · INAll India Institute of Medical Sciences, NagpurInstitute of Medical Sciences · INRegional Institute of Medical Sciences · INSparsh Hospital · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDelayed cord clamping (DCC) is practiced worldwide, as standard care in both term and preterm babies. Our aim was to determine the hemodynamic effects of DCC on transitional circulation. MATERIAL AND

methodsThis prospective observational study was carried out in a tertiary care hospital, at Pune, India, from May 2018 to October 2019.Term neonates born during the study period were included. The primary outcome variables of the study were right ventricular output (RVO), left ventricular output (LVO), superior vena cava (SVC) flow (ml/kg/min) and heart rate(HR) at 12 ± 6 and 48 ± 6 h of life measured by point of care functional echocardiography. Inter-observer and intra-observer variability was calculated for these parameters.

resultsOut of a total of 2744 deliveries during the study period, 620 babies were included. Mean gestational age of the enrolled babies was 38.96 ± 1.08 weeks and mean birth weight was 2.9 ± 0.39 kg. Mean heart rate of babies recorded at 12 ± 6 h of life was 127 beats per minute (bpm) whereas it was 128 bpm at 48 ± 6 h of life. RVO {mean (SD)} was 209.55(44.89) and 205.85(46.35) ml/kg/min, LVO {mean (SD)} was 133.68(31.15) and 134.78(29.84) ml/kg/min whereas SVC flow {mean (SD)} was 106.85(26.21) and 109.29(25.11) ml/kg/min at 12 ± 6 and 48 ± 6 h of life respectively. There was good intra-observer agreement in all the variables. SGA babies had a significantly higher heart rate at 12 ± 6 h of life as compared to AGA babies, although this difference in heart rate could not be appreciated at 48 ± 6 h of life. However SGA babies had a higher LVO, RVO and SVC flow than AGA babies at both the time points of observation.

conclusionAfter DCC there is less fluctuation in the hemodynamic parameters (heart rate, cardiac output) at the two time points of observation.. As compared to AGA babies, SGA babies had a significantly higher baseline heart rate, LVO, RVO and SVC flow. LVO of SGA babies after delayed cord clamping is found to be significantly lower than LVO seen in other studies, favoring the cardio-stabilizing effect of DCC. BRIEF RATIONALE: This is the first study with a large sample size evaluating the hemodynamic effects of DCC in term neonates by functional echocardiography. The normative data of heart rate and cardiac output of term, stable babies with small for gestational age(SGA) as a special subgroup undergoing DCC requires further evaluation.

Indexed as

Infant, PrematureUmbilical Cord ClampingVena Cava, SuperiorConstrictionFemaleHemodynamicsHumansIndiaInfantInfant, NewbornPregnancyUmbilical CordDelayed cord clamping (DCC)Functional echocardiography (FnEcho)Transitional circulation

Identifiers

PMID35524194
PMCPMC9074198
OpenAlexW4229035793

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.