Evidence map›Paper›PMID 35520262›Full record

ArticleRSC advances2019

Contact lenses for continuous corneal temperature monitoring.

Rosalia Moreddu, Mohamed Elsherif, Haider Butt, Daniele Vigolo, Ali K Yetisen

Open access · goldAbstract read
In one paragraph

Article in RSC advances, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
8.7field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 69 citations in OpenAlex.

  1. Recent advances in smart contact lenses.Biosensors & bioelectronics: X · 2026
    Article
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Review
  9. Article
  10. Review
  11. Article
  12. Review
  13. Review
  14. Review
  15. Article
  16. pH-Sensitive Biomaterials for Drug Delivery.Molecules (Basel, Switzerland) · 2020
    Review
  17. Review
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Rosalia MoredduDepartment of Chemical Engineering, Imperial College London London SW7 2AZ UK r.moreddu18@imperial.ac.uk.ORCID https://orcid.org/0000-0002-0332-1606
Mohamed ElsherifSchool of Chemical Engineering, University of Birmingham Birmingham B15 2TT UK.
Haider ButtDepartment of Mechanical Engineering, Khalifa University Abu Dhabi 127788 United Arab Emirates.ORCID https://orcid.org/0000-0003-2434-9525
Daniele VigoloSchool of Chemical Engineering, University of Birmingham Birmingham B15 2TT UK.ORCID https://orcid.org/0000-0002-8265-9882
Ali K YetisenDepartment of Chemical Engineering, Imperial College London London SW7 2AZ UK r.moreddu18@imperial.ac.uk.
Transnational Press LondonUniversity of Birmingham · GBKhalifa University of Science and Technology · AE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Temperature variation is a ubiquitous medical sign to monitor ocular conditions including dry eye disease (DED), glaucoma, carotid artery stenosis, diabetic retinopathy, and vascular neuritis. The ability to measure OST in real time is desirable in point-of-care diagnostics. Here, we developed minimally invasive contact lens temperature sensors for continuous monitoring of the corneal temperature. The contact lens sensor consisted of a laser patterned commercial contact lens embedding temperature-sensitive Cholesteric Liquid Crystals (CLCs), which exhibited a fully reversible temperature-dependent color change in the visible spectrum. The contact lens allowed the corneal temperature to be mapped in four key areas, at distances of 0.0, 1.0, 3.0, and 5.0 mm from the pupil's edge. Liquid crystals exhibited a wavelength shift from 738 ± 4 nm to 474 ± 4 nm upon increasing the temperature from 29.0 °C to 40.0 °C, with a time responsivity of 490 ms and a negligible hysteresis. Readouts were performed using a smartphone, which output RGB triplets associated to temperature values. Contact lens sensors based on CLCs were fitted and tested on an

Identifiers

PMID35520262
PMCPMC9063335
OpenAlexW2936678671

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.