Evidence map›Paper›PMID 35515396›Full record

ArticleRSC advances2020

A 3-D NanoMagnetoElectrokinetic model for ultra-high precision assembly of ferromagnetic NWs using magnetic-field assisted dielectrophoresis.

Sachin K Singh, Md Mahadi Rajib, Justine L Drobitch, Jayasimha Atulasimha, Supriyo Bandyopadhyay, Arunkumar Subramanian

Erratum issuedAbstract read
In one paragraph

Article in RSC advances, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Sachin K SinghDepartment of Mechanical and Industrial Engineering, University of Illinois at Chicago Chicago IL 60607 USA sarun@uic.edu.ORCID https://orcid.org/0000-0003-3427-052X
Md Mahadi RajibDepartment of Mechanical and Nuclear Engineering, Virginia Commonwealth University Richmond VA 23284 USA.
Justine L DrobitchDepartment of Electrical and Computer Engineering, Virginia Commonwealth University Richmond VA 23284 USA.
Jayasimha AtulasimhaDepartment of Mechanical and Nuclear Engineering, Virginia Commonwealth University Richmond VA 23284 USA.
Supriyo BandyopadhyayDepartment of Electrical and Computer Engineering, Virginia Commonwealth University Richmond VA 23284 USA.
Arunkumar SubramanianDepartment of Mechanical and Industrial Engineering, University of Illinois at Chicago Chicago IL 60607 USA sarun@uic.edu.ORCID https://orcid.org/0000-0001-8779-391X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This report presents a three-dimensional (3-D) magnetoelectrokinetic model to investigate a new approach to magnetic-field assisted dielectrophoresis for ultra-high precision and parallel assembly of ferromagnetic Ni nanowires (NWs) on silicon chips. The underlying assembly methodology relies on a combination of electric and magnetic fields to manipulate single nanowires from a colloidal suspension and yield their assembly on top of electrodes with better than 25 nm precision. The electric fields and the resultant dielectrophoretic forces are generated through the use of patterned gold nanoelectrodes, and deliver long-range forces that attract NWs from farther regions of the workspace and bring them in proximity to the nanoelectrodes. Next, magnetic-fields generated by cobalt magnets, which are stacked on top of the gold nanoelectrodes at their center and pre-magnetized using external magnetic fields, deliver short range forces to capture the nanowires precisely on top of the nanomagnets. The 3-D NanoMagnetoElectrokinetic model, which is built using a finite element code in COMSOL software and with further computations in MATLAB, computes the trajectory and final deposition location as well as orientation for all possible starting locations of a Ni NW within the assembly workspace. The analysis reveals that magnetic-field assisted dielectrophoresis achieves ultra-high precision assembly of NWs on top of the cobalt nanomagnets from a 42% larger workspace volume as compared to pure dielectrophoresis and thereby, establishes the benefits of adding magnetic fields to the assembly workspace. Furthermore, this approach is combined with a strategy to confine the suspension within the reservoir that contains a high density of favorable NW starting locations to deliver high assembly yields for landing NWs on top of contacts that are only twice as wide as the NWs.