ArticleRSC advances2019
A contact lens promising for non-invasive continuous intraocular pressure monitoring.
Article in RSC advances, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 45 citations in OpenAlex.
- An LSPR-Active AuNP-Silicone Hydrogel Contact Lens for Continuous Ocular Strain Sensing: From Engineering Design to In Vivo Validation.Biosensors · 2026Article
- Wirelessly Interrogated, Implantable Capacitive MEMS Sensors for Continuous Intraocular Pressure Monitoring.Sensors (Basel, Switzerland) · 2026Article
- Current and Emerging Technologies for Continuous Intraocular Pressure Monitoring in the Control of Glaucoma Progression: A Scoping Review.Journal of clinical medicine · 2025Review
- Neuroprosthetic contact lens enabled sensorimotor system for point-of-care monitoring and feedback of intraocular pressure.Nature communications · 2024Article
- Advancements in Wearable and Implantable Intraocular Pressure Biosensors for Ophthalmology: A Comprehensive Review.Micromachines · 2023Review
- Soft Electronics for Health Monitoring Assisted by Machine Learning.Nano-micro letters · 2023Review
- Lab-on-a-Contact Lens: Recent Advances and Future Opportunities in Diagnostics and Therapeutics.Advanced materials (Deerfield Beach, Fla.) · 2022Review
- A Meta-Analysis of Wearable Contact Lenses for Medical Applications: Role of Electrospun Fiber for Drug Delivery.Polymers · 2022Review
- Real-Time Monitoring of Intraocular Pressure in Glaucoma Patients Using Wearable Mobile Medicine Devices.Journal of healthcare engineering · 2022Article
- Ophthalmic Sensors and Drug Delivery.ACS sensors · 2021Review
- Smart Contact Lenses with a Transparent Silver Nanowire Strain Sensor for Continuous Intraocular Pressure Monitoring.ACS applied bio materials · 2021Article
- Wearable and Implantable Intraocular Pressure Biosensors: Recent Progress and Future Prospects.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2021Review
- Wearable Contact Lens Sensor for Non-invasive Continuous Monitoring of Intraocular Pressure.Micromachines · 2021Article
- Stimulus-Responsive Contact Lens for IOP Measurement or Temperature-Triggered Drug Release.Translational vision science & technology · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Intraocular pressure (IOP) is the key indicator to assess the risk for and status of glaucoma patients, and medication at high IOP values slows down exacerbation of glaucoma. However, the IOP value is subject to circadian variation and cannot be measured continuously in clinical practice. Herein, we have fabricated a contact lens with a Wheatstone bridge circuit for non-invasive monitoring of IOP. A metal electrode has been used as a strain gauge to measure the weak deformation of the eyeball caused by IOP variation. Tests on a model eye indicate that the contact lens exhibits a high sensitivity of 20 μV mmHg
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.