Evidence map›Paper›PMID 35512685›Full record

ArticleSleep2022

Hypocretin-1 measurements in cerebrospinal fluid using radioimmunoassay: within and between assay reliability and limit of quantification.

Adrienne Elisabeth van der Hoeven, Kevin van Waaij, Denise Bijlenga, Frederik Willem Cornelis Roelandse, Sebastiaan Overeem, Jaap Adriaan Bakker, Rolf Fronczek, Gert Jan Lammers

Open access · hybridAbstract read
In one paragraph

Article in Sleep, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.9field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Adrienne Elisabeth van der HoevenDepartment of Neurology, Leiden University Medical Center, Leiden, the Netherlands.ORCID 0000-0002-3255-8506
Kevin van WaaijDepartment of Neurology, Leiden University Medical Center, Leiden, the Netherlands.
Denise BijlengaDepartment of Neurology, Leiden University Medical Center, Leiden, the Netherlands.ORCID 0000-0002-5169-9830
Frederik Willem Cornelis RoelandseDepartment of Clinical Chemistry and Laboratory Medicine, Leiden University Medical Center, Leiden, the Netherlands.
Sebastiaan OvereemSleep Medicine Center, Kempenhaeghe, Heeze, the Netherlands.ORCID 0000-0002-6445-9836
Jaap Adriaan BakkerDepartment of Clinical Chemistry and Laboratory Medicine, Leiden University Medical Center, Leiden, the Netherlands.ORCID 0000-0002-2918-7361
Rolf FronczekDepartment of Neurology, Leiden University Medical Center, Leiden, the Netherlands.ORCID 0000-0002-1935-7603
Gert Jan LammersDepartment of Neurology, Leiden University Medical Center, Leiden, the Netherlands.
Leiden University Medical Center · NLKempenhaeghe · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

STUDY

objectivesThe most sensitive and specific investigative method for the diagnosis of narcolepsy type 1 (NT1) is the determination of hypocretin-1 (orexin-A) deficiency (≤110 pg/mL) in cerebrospinal fluid using a radioimmunoassay (RIA). We aimed to assess the reliability of the Phoenix Pharmaceuticals hypocretin-1 RIA, by determining the lower limit of quantification (LLOQ), the variability around the cutoff of 110 pg/mL, and the inter- and intra-assay variability.

methodsRaw data of 80 consecutive hypocretin-1 RIAs were used to estimate the intra- and inter-assay coefficient of variation (CV). The LLOQ was established and defined as the lowest converted concentration with a CV <25%; the conversion is performed using a harmonization sample which is internationally used to minimize variation between RIAs.

resultsThe mean intra-assay CV was 4.7%, while the unconverted inter-assay CV was 28.3% (18.5% excluding 2 outliers) and 7.5% when converted to international values. The LLOQ was determined as 27.9 pg/mL. The intra-assay CV of RIAs with lower specific radioactive activity showed a median of 5.6% (n = 41, range 1.6%-17.0%), which was significantly higher than in RIAs with higher specific activity (n = 36; median 3.2%, range 0.4%-11.6%, p = .013). The CV around the 110 pg/mL cutoff was <7%.

conclusionsHypocretin-1 RIAs should always be harmonized using standard reference material. The specific activity of an RIA has a significant impact on its reliability, because of the decay of 125I radioactivity. Values around the hypocretin-1 cut-off can reliably be measured. Hypocretin-1 concentrations below 28 pg/mL should be reported as "undetectable" when measured with the Phoenix Pharmaceuticals RIA. CLINICAL TRIAL INFORMATION: This study is not registered in a clinical trial register, as it has a retrospective database design.

Indexed as

Iodine RadioisotopesNarcolepsyHumansOrexinsPharmaceutical PreparationsRadioimmunoassayReproducibility of ResultsRetrospective StudiesIodine-125Iodine RadioisotopesOrexinsPharmaceutical Preparationsinter-assay coefficient of variationintra-assay coefficient of variationnarcolepsyorexin-A

Identifiers

PMID35512685
PMCPMC9272241
OpenAlexW4228997606

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.