Evidence map›Paper›PMID 35511898›Full record

ArticlePloS one2022

Using standard-length compactors to implant short humeral stems in total shoulder arthroplasty: A cadaver study of humeral stem alignment.

Stanislas Gunst, Ana Nigues, Jérôme Vogels, Elvire Servien, Sébastien Lustig, Laurent Nove-Josserand, Philippe Collotte

Abstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Stanislas GunstOrthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.ORCID 0000-0002-1038-105X
Ana NiguesOrthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.
Jérôme VogelsHand and Upper Extremity Surgical Institute, Clinique du Medipole, Villeurbanne, France.
Elvire ServienOrthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.
Sébastien LustigOrthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.
Laurent Nove-JosserandRamsay Générale de Santé, Jean Mermoz Private Hospital, Centre Orthopédique Santy, Lyon, France.
Philippe CollotteRamsay Générale de Santé, Jean Mermoz Private Hospital, Centre Orthopédique Santy, Lyon, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundShort-stem implants in shoulder arthroplasty were recently developed and reported clinical outcomes are good. However, radiological analysis often reveals humeral stem misalignment in the frontal plane, along with high filling ratios that can lead to proximal bone remodeling under stress shielding. The aim of this cadaveric study was to test whether using compactors for standard-length (> 100 mm) stems to implant short (< 100 mm) stems reduces the risk of stem misalignment without compromising in terms of a higher filling ratio.

methodsIn a cadaveric study, twenty short stems were implanted using instrumentation for standard-length stems. Alignment and filling ratios were evaluated on anteroposterior radiographs for both the compactors and the stems. The angular deviations (α) from the humeral axis of the compactors and the short stems were measured. Misalignment was defined as |α| > 5°. Metaphyseal and diaphyseal filling ratios were calculated and defined as either high (≥ 0.7) or low (< 0.7).

resultsThe median angular deviations of the compactors and the short stems were respectively 1.6° (range, 0.03 to 5.9°) and 1.3° (range, 0.3 to 9.6°). Nineteen of the 20 compactors (95%) and 17/20 short stems (85%) were correctly aligned. The proportions of correctly aligned compactors and stems were not significantly different (95% CI, -0.33 to 0.11; Z-test of proportions p = .60), and the respective angular deviations were significantly correlated (Spearman ρ = .60, p = 0.006). The diaphyseal and metaphyseal filling ratios of the compactors and the stems were all low.

conclusionsIn this series of 20 implants in cadavers, the narrow short humeral stems implanted with compactors for standard-length stems were correctly aligned with the humeral axis. This approach may be a way to achieve both correct frontal alignment and low filling ratios.

Indexed as

Arthroplasty, Replacement, ShoulderShoulder JointShoulder ProsthesisCadaverHumansHumerusProsthesis DesignTreatment Outcome

Identifiers

PMID35511898
PMCPMC9070928

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.