ArticleInternational journal of computer assisted radiology and surgery2022
A particle filter approach to dynamic kidney pose estimation in robotic surgical exposure.
Article in International journal of computer assisted radiology and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Modern Image-Guided Surgery: A Narrative Review of Medical Image Processing and Visualization.Sensors (Basel, Switzerland) · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
purposeTraditional soft tissue registration methods require direct intraoperative visualization of a significant portion of the target anatomy in order to produce acceptable surface alignment. Image guidance is therefore generally not available during the robotic exposure of structures like the kidneys which are not immediately visualized upon entry into the abdomen. This paper proposes guiding surgical exposure with an iterative state estimator that assimilates small visual cues into an a priori anatomical model as exposure progresses, thereby evolving pose estimates for the occluded structures of interest.
methodsIntraoperative surface observations of a right kidney are simulated using endoscope tracking and preoperative tomography from a representative robotic partial nephrectomy case. Clinically relevant random perturbations of the true kidney pose are corrected using this sequence of observations in a particle filter framework to estimate an optimal similarity transform for fitting a patient-specific kidney model at each step. The temporal response of registration error is compared against that of serial rigid coherent point drift (CPD) in both static and simulated dynamic surgical fields, and for varying levels of observation persistence.
resultsIn the static case, both particle filtering and persistent CPD achieved sub-5 mm accuracy, with CPD processing observations 75% faster. Particle filtering outperformed CPD in the dynamic case under equivalent computation times due to the former requiring only minimal persistence.
conclusionThis proof-of-concept simulation study suggests that Bayesian state estimation may provide a viable pathway to image guidance for surgical exposure in the abdomen, especially in the presence of dynamic intraoperative tissue displacement and deformation.
Indexed as
Identifiers
35511394What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.