Evidence map›Paper›PMID 35511021›Full record

ArticleJournal of synchrotron radiation2022

Design and performance of a dedicated coherent X-ray scanning diffraction instrument at beamline NanoMAX of MAX IV.

Dina Carbone, Sebastian Kalbfleisch, Ulf Johansson, Alexander Björling, Maik Kahnt, Simone Sala, Tomas Stankevic, Angel Rodriguez-Fernandez, Björn Bring, Zdenek Matej and 12 more

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. 3D imaging of magnetic domains in NdJournal of synchrotron radiation · 2024
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

22 authors.

Dina CarboneMAX IV Laboratory, Lund University, 22100 Lund, Sweden.ORCID 0000-0003-1017-6213
Sebastian KalbfleischMAX IV Laboratory, Lund University, 22100 Lund, Sweden.
Ulf JohanssonMAX IV Laboratory, Lund University, 22100 Lund, Sweden.ORCID 0000-0002-5189-1742
Alexander BjörlingMAX IV Laboratory, Lund University, 22100 Lund, Sweden.
Maik KahntMAX IV Laboratory, Lund University, 22100 Lund, Sweden.ORCID 0000-0003-4332-1202
Simone SalaMAX IV Laboratory, Lund University, 22100 Lund, Sweden.ORCID 0000-0002-1949-0877
Tomas StankevicMAX IV Laboratory, Lund University, 22100 Lund, Sweden.
Angel Rodriguez-FernandezMAX IV Laboratory, Lund University, 22100 Lund, Sweden.ORCID 0000-0003-0587-5263
Björn BringMAX IV Laboratory, Lund University, 22100 Lund, Sweden.
Zdenek MatejMAX IV Laboratory, Lund University, 22100 Lund, Sweden.ORCID 0000-0002-2585-573X
Paul BellMAX IV Laboratory, Lund University, 22100 Lund, Sweden.
David ErbMAX IV Laboratory, Lund University, 22100 Lund, Sweden.ORCID 0000-0002-1164-0244
Vincent HardionMAX IV Laboratory, Lund University, 22100 Lund, Sweden.
Clemens WeningerMAX IV Laboratory, Lund University, 22100 Lund, Sweden.
Hussein Al-SallamiMAX IV Laboratory, Lund University, 22100 Lund, Sweden.
Julio Lidon-SimonMAX IV Laboratory, Lund University, 22100 Lund, Sweden.
Stefan CarlsonMAX IV Laboratory, Lund University, 22100 Lund, Sweden.
Annika JerreboMAX IV Laboratory, Lund University, 22100 Lund, Sweden.
Brian Norsk JensenMAX IV Laboratory, Lund University, 22100 Lund, Sweden.
Anders BjermoMAX IV Laboratory, Lund University, 22100 Lund, Sweden.
Karl ÅhnbergMAX IV Laboratory, Lund University, 22100 Lund, Sweden.
Linus RoslundMAX IV Laboratory, Lund University, 22100 Lund, Sweden.

Funding

Svenska Forskningsrådet Formas 2019-02496Vetenskapsrådet 2018-07152VINNOVA 2018-04969
6 · The paper itself

Abstract

The diffraction endstation of the NanoMAX beamline is designed to provide high-flux coherent X-ray nano-beams for experiments requiring many degrees of freedom for sample and detector. The endstation is equipped with high-efficiency Kirkpatrick-Baez mirror focusing optics and a two-circle goniometer supporting a positioning and scanning device, designed to carry a compact sample environment. A robot is used as a detector arm. The endstation, in continued development, has been in user operation since summer 2017.

Indexed as

coherent X-rayshard X-ray nanoprobesinstrumentationscanning X-ray diffractionX-ray imaging

Identifiers

PMID35511021
PMCPMC9070697

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.