Evidence map›Paper›PMID 35511004›Full record

ArticleJournal of synchrotron radiation2022

X-ray reflectivity from curved surfaces as illustrated by a graphene layer on molten copper.

Oleg V Konovalov, Valentina Belova, Francesco La Porta, Mehdi Saedi, Irene M N Groot, Gilles Renaud, Irina Snigireva, Anatoly Snigirev, Maria Voevodina, Chen Shen and 3 more

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. The laser pump X-ray probe system at LISA P08 PETRA III.Journal of synchrotron radiation · 2024
    Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Oleg V KonovalovESRF - The European Synchrotron, 71 Avenue des Martyrs, 38043 Grenoble, France.ORCID 0000-0002-0390-5900
Valentina BelovaESRF - The European Synchrotron, 71 Avenue des Martyrs, 38043 Grenoble, France.ORCID 0000-0002-8142-2090
Francesco La PortaESRF - The European Synchrotron, 71 Avenue des Martyrs, 38043 Grenoble, France.
Mehdi SaediLeiden Institute of Chemistry, Leiden University, PO Box 9502, 2300 RA Leiden, The Netherlands.ORCID 0000-0003-4958-9752
Irene M N GrootLeiden Institute of Chemistry, Leiden University, PO Box 9502, 2300 RA Leiden, The Netherlands.
Gilles RenaudUniv. Grenoble Alpes, CEA, IRIG/MEM/NRS, 38000 Grenoble, France.
Irina SnigirevaESRF - The European Synchrotron, 71 Avenue des Martyrs, 38043 Grenoble, France.ORCID 0000-0003-3481-2202
Anatoly SnigirevImmanuel Kant Baltic Federal University, 14 Nevskogo, 236041 Kaliningrad, Russian Federation.ORCID 0000-0002-8892-1925
Maria VoevodinaImmanuel Kant Baltic Federal University, 14 Nevskogo, 236041 Kaliningrad, Russian Federation.
Chen ShenDeutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.ORCID 0000-0002-7855-1764
Andrea SartoriInstitute for Experimental and Applied Physics, Kiel University, Olshausenstrasse 40, 24098 Kiel, Germany.ORCID 0000-0003-0740-8423
Bridget M MurphyInstitute for Experimental and Applied Physics, Kiel University, Olshausenstrasse 40, 24098 Kiel, Germany.ORCID 0000-0002-1354-2381
Maciej JankowskiESRF - The European Synchrotron, 71 Avenue des Martyrs, 38043 Grenoble, France.ORCID 0000-0002-3796-0529

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The X-ray reflectivity technique can provide out-of-plane electron-density profiles of surfaces, interfaces, and thin films, with atomic resolution accuracy. While current methodologies require high surface flatness, this becomes challenging for naturally curved surfaces, particularly for liquid metals, due to the very high surface tension. Here, the development of X-ray reflectivity measurements with beam sizes of a few tens of micrometres on highly curved liquid surfaces using a synchrotron diffractometer equipped with a double crystal beam deflector is presented. The proposed and developed method, which uses a standard reflectivity θ-2θ scan, is successfully applied to study in situ the bare surface of molten copper and molten copper covered by a graphene layer grown in situ by chemical vapor deposition. It was found that the roughness of the bare liquid surface of copper at 1400 K is 1.25 ± 0.10 Å, while the graphene layer is separated from the liquid surface by a distance of 1.55 ± 0.08 Å and has a roughness of 1.26 ± 0.09 Å.

Indexed as

curved surfacesmethodssynchrotronX-ray reflectivity

Identifiers

PMID35511004
PMCPMC9070704

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.