Overcoming supply disruptions during pandemics by utilizing found hardware for open source gentle ventilation.

S Oberloier, N Gallup, J M Pearce

Abstract read
In one paragraph

Article in HardwareX, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

S OberloierDepartment of Electrical & Computer Engineering, Michigan Technological University, Houghton, MI 49931, USA.
N GallupDepartment of Biomedical Engineering and Mechanical Engineering, Michigan Technological University, Houghton, MI 49931, USA.
J M PearceDepartment of Electrical & Computer Engineering, Western University, London, ON N6A 3K7, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This article details the design of an open source emergency gentle ventilator (gentle-vent) framework that can be used in periods of scarcity. Although it is not a medical device, the system utilizes a wide range of commonly-available components that are combined using basic electronics skills to achieve the desired performance. The main function of the gentle-vent is to generate a calibrated pressure wave at the pump to provide support to the patient's breathing. Each gentle-vent permutation was tested using a DIY manometer as it would be utilized in the field in low-resource settings and validated with an open source VentMon. The most rudimentary implementation costs less than $40.

Indexed as

Appropriate technologyCOVID-19ImprovisationMedical equipmentOpen hardwareOpen sourceRepurposed hardwareVentilation