ArticleScientific reports2022
Quantitative EEG may predict weaning failure in ventilated patients on the neurological intensive care unit.
Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06359977 (The Effect of Quantitative Electroencephalography Combined With Ultrasound and Sputum Volume on Predicting Weaning Failure in Neurocritical Patients), which is not on this map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
The Effect of Quantitative Electroencephalography Combined With Ultrasound and Sputum Volume on Predicting Weaning Failure in Neurocritical Patients
Who cites it
4 citing papers in PubMed, 7 citations in OpenAlex.
- Voices of patients' relatives to support weaning from mechanical ventilation: a randomized trial.Brain communications · 2025Trial
- Monitoring of invasive assisted mechanical ventilation: a good clinical practice document by the Italian Society of Anesthesia, Analgesia, Resuscitation, and Intensive Care (SIAARTI).Journal of anesthesia, analgesia and critical care · 2025Review
- Challenges in Transitioning from Controlled to Assisted Ventilation in Acute Respiratory Distress Syndrome (ARDS) Management.Journal of clinical medicine · 2024Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Neurocritical patients suffer from a substantial risk of extubation failure. The aim of this prospective study was to analyze if quantitative EEG (qEEG) monitoring is able to predict successful extubation in these patients. We analyzed EEG-monitoring for at least six hours before extubation in patients receiving mechanical ventilation (MV) on our neurological intensive care unit (NICU) between November 2017 and May 2019. Patients were divided in 2 groups: patients with successful extubation (SE) versus patients with complications after MV withdrawal (failed extubation; FE), including reintubation, need for non-invasive ventilation (NIV) or death. Bipolar six channel EEG was applied. Unselected raw EEG signal underwent automated artefact rejection and Short Time Fast Fourier Transformation. The following relative proportions of global EEG spectrum were analyzed: relative beta (RB), alpha (RA), theta (RT), delta (RD) as well as the alpha delta ratio (ADR). Coefficient of variation (CV) was calculated as a measure of fluctuations in the different power bands. Mann-Whitney U test and logistic regression were applied to analyze group differences. 52 patients were included (26 male, mean age 65 ± 17 years, diagnosis: 40% seizures/status epilepticus, 37% ischemia, 13% intracranial hemorrhage, 10% others). Successful extubation was possible in 40 patients (77%), reintubation was necessary in 6 patients (12%), 5 patients (10%) required NIV, one patient died. In contrast to FE patients, SE patients showed more stable EEG power values (lower CV) considering all EEG channels (RB: p < 0.0005; RA: p = 0.045; RT: p = 0.045) with RB as an independent predictor of weaning success in logistic regression (p = 0.004). The proportion of the EEG frequency bands (RB, RA RT, RD) of the entire EEG power spectrum was not significantly different between SE and FE patients. Higher fluctuations in qEEG frequency bands, reflecting greater fluctuation in alertness, during the hours before cessation of MV were associated with a higher rate of complications after extubation in this cohort. The stability of qEEG power values may represent a non-invasive, examiner-independent parameter to facilitate weaning assessment in neurocritical patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.