ArticleJournal of breath research2022
A low cost, easy-to-assemble, open-source modular mobile sampler design for thermal desorption analysis of breath and environmental VOCs.
Article in Journal of breath research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Data-Driven Approach to Modeling Microfabricated Chemical Sensor Manufacturing.Analytical chemistry · 2024Article
- Predominant SARS-CoV-2 variant impacts accuracy when screening for infection using exhaled breath vapor.Communications medicine · 2022Article
- Glass-to-Glass Fusion Bonding Quality and Strength Evaluation with Time, Applied Force, and Heat.Micromachines · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Exhaled breath vapor contains hundreds of volatile organic compounds (VOCs), which are the byproducts of health and disease metabolism, and they have clinical and diagnostic potential. Simultaneous collection of breath VOCs and background environmental VOCs is important to ensure analyses eliminate exogenous compounds from clinical studies. We present a mobile sampling system to extract gaseous VOCs onto commercially available sorbent-packed thermal desorption tubes. The sampler can be connected to a number of commonly available disposable and reusable sampling bags, in the case of this study, a Tedlar bag containing a breath sample. Alternatively, the inlet can be left open to directly sample room or environmental air when obtaining a background VOC sample. The system contains a screen for the operator to input a desired sample volume. A needle valve allows the operator to control the sample flow rate, which operates with an accuracy of -1.52 ± 0.63% of the desired rate, and consistently generated that rate with 0.12 ± 0.06% error across repeated measures. A flow pump, flow sensor and microcontroller allow volumetric sampling, as opposed to timed sampling, with 0.06 ± 0.06% accuracy in the volume extracted. Four samplers were compared by sampling a standard chemical mixture, which resulted in 6.4 ± 4.7% error across all four replicate modular samplers to extract a given VOC. The samplers were deployed in a clinical setting to collect breath and background/environmental samples, including patients with active SARS-CoV-2 infections, and the device could easily move between rooms and can undergo required disinfection protocols to prevent transmission of pathogens on the case exterior. All components required for assembly are detailed and are made publicly available for non-commercial use, including the microcontroller software. We demonstrate the device collects volatile compounds, including use of chemical standards, and background and breath samples in real use conditions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.