ArticleTranslational vision science & technology2022
Evaluation of the Optical Aspects of the Ophthalmic Viscosurgical Device During Femtosecond Laser-Assisted Cataract Surgery.
Article in Translational vision science & technology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 2 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: In femtosecond laser-assisted cataract surgery (FLACS), capsulorhexis can be performed with an ophthalmic viscosurgical device (OVD) filled in the anterior chamber. We aimed to investigate changes in the laser properties in various optical aspects, such as focal shifting, reflection, and absorption associated with OVD. Methods: Simulation was achieved by calculating the laser power attenuation due to reflection and spot size change using the Gullstrand eye model. Additionally, we calculated the absorption coefficient by measuring the laser power passing through the OVD with a laser meter and evaluated the effect of absorption by the OVD. Results: In our simulation, power attenuation due to reflection was a maximum of 0.07%, and power attenuation was 0.08% even when considering the change according to the incident angle. Power attenuation due to the change of the spot size at the focus was 0.005%. Owing to the absorption of the OVD, a power increase of up to 13.5% was required for an anterior chamber depth of 3.0 mm to obtain the same effect as the aqueous humor. Conclusions: The main reason for laser power attenuation associated with OVD was laser absorption through the OVD, and could also be caused by laser cavitation bubbles. To complete a safe capsulotomy during FLACS, the laser power should be increased appropriately, considering the absorption by the OVD in the anterior chamber. Translational Relevance: The study results can be applied to calculate the optimal femtosecond laser energy to achieve complete capsulotomy during FLACS in the presence of anterior chamber OVD.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.