Evidence map›Paper›PMID 35505598›Full record

ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2023

Verification of software-based preoperative simulation of flow diverters in clinical cases.

Yixuan Wang, Xinjian Yang, Wei Zhu, Xinlan Wang, Yangyang Yao, Wangsheng Lu, Guangming Yang, Lan Qin, Jian Liu, Miao Li

Open access · greenAbstract read
In one paragraph

Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.1field-weighted citation impact, top 55% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Yixuan WangDepartment of Neurosurgery, The China-Japan Union Hospital, Jilin University, Changchun, China.ORCID 0000-0003-2367-625X
Xinjian YangDepartment of Interventional Neuroradiology, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, China.ORCID 0000-0001-7306-0125
Wei ZhuDepartment of Interventional Neuroradiology, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
Xinlan WangDepartment of Neurosurgery, The China-Japan Union Hospital, Jilin University, Changchun, China.
Yangyang YaoUnionStrong (Beijing) Technology Co. Ltd, Beijing, China.
Wangsheng LuUnionStrong (Beijing) Technology Co. Ltd, Beijing, China.
Guangming YangUnionStrong (Beijing) Technology Co. Ltd, Beijing, China.
Lan QinUnionStrong (Beijing) Technology Co. Ltd, Beijing, China.
Jian LiuDepartment of Interventional Neuroradiology, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, China.ORCID 0000-0002-5454-2847
Miao LiDepartment of Neurosurgery, The China-Japan Union Hospital, Jilin University, Changchun, China.ORCID 0000-0001-6672-8692
Capital Medical University · CNUnion Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThe authors sought to verify the use of a preoperative simulation software for the treatment of intracranial aneurysms using flow diverters (FDs) based on three-dimensional rotational angiography (3DRA) data.

methodsBased on 3DRA data, the preoperative simulation software (UKNOW) was used to simulate the deployment of virtual FDs. The length and dimensions of virtual and real devices were compared. The deployment plan recommended by the UKNOW software was preliminarily used to complete implantations in the real world. During the experiment, experienced neurointerventional experts were responsible for supervising and judging information such as the length, dimension, and deployment location of the FDs.

resultsThis study retrospectively analyzed the data of 29 patients who received FD treatment. There was no statistical difference between the length of the real device and the virtual device (

conclusionsUKNOW software could accurately simulate the length and deployment position of the real FDs and provide suitable device dimensions.

Indexed as

Embolization, TherapeuticIntracranial AneurysmComputer SimulationHumansRetrospective StudiesSoftwareStentsFlow diverterpipeline embolization devicepreoperative simulationsoftware

Identifiers

PMID35505598
PMCPMC10549721
OpenAlexW4225412062

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.